Periodic Nonlinear Error Analysis and Compensation of a Single-Excited Petal-Shaped Capacitive Encoder to Achieve

Bo Hou1, Bin Zhou2, Xiang Li3

  • 1Engineering Research Center for Navigation Technology, Department of Precision Instrument, Tsinghua University, Beijing 100084, China. houb15@mails.tsinghua.edu.cn.

Related Concept Videos

Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
100.5K
Accuracy and Errors in Hypothesis Testing01:13

Accuracy and Errors in Hypothesis Testing

Hypothesis testing is a fundamental statistical tool that begins with the assumption that the null hypothesis H0 is true. During this process, two types of errors can occur: Type I and Type II. A Type I error refers to the incorrect rejection of a true null hypothesis, while a Type II error involves the failure to reject a false null hypothesis.
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...
573
Capacitance: Single-Phase And Three-Phase Line01:25

Capacitance: Single-Phase And Three-Phase Line

In electrical power systems, understanding the capacitance of transmission lines is fundamental for efficient operation.
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
589
Improving Translational Accuracy02:07

Improving Translational Accuracy

Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
14.1K
Nonlinear Pharmacokinetics: Causes of Nonlinearity01:22

Nonlinear Pharmacokinetics: Causes of Nonlinearity

Nonlinearity in drug pharmacokinetics is caused by various factors influencing how a drug is absorbed, distributed, metabolized, and excreted. Understanding these nonlinear processes is crucial for predicting drug behavior in the body and optimizing drug dosing regimens.
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
719
Dosage Compensation02:50

Dosage Compensation

In animals, gender is determined by the number and type of sex chromosome. For example, human females have two X chromosomes, and males have one X and one Y chromosome, whereas C.elegans with one X chromosome is a male, and the one with two X chromosomes is a hermaphrodite.
In addition to sexual development, the X chromosome has genes involved in autosomal functions such as brain development and the immune system. Therefore, males and females with  distinct numbers of X chromosomes will...
7.1K