Related Experiment Video
Updated: Jan 24, 2026

Determining the Likelihood of Variant Pathogenicity Using Amino Acid-level Signal-to-Noise Analysis of Genetic Variation
Published on: January 16, 2019
Bandwidth extension of narrowband-signal intensity calculation using additive, low-level broadband noise
Mylan R Cook1, Kelli F Succo1, Kent L Gee1
1Department of Physics and Astronomy, Brigham Young University, N283 ESC Provo, Utah 84602, USA.
Abstract:
Calculation of acoustic intensity using the phase and amplitude gradient estimator (PAGE) method has been shown to increase the effective upper frequency limit beyond the traditional p-p method when the source of interest is broadband in frequency [Torrie, Whiting, Gee, Neilsen, and Sommerfeldt, Proc. Mtgs. Acoust. 23, 030005 (2015)]. PAGE processing calculates intensity for narrowband sources without bias error up to the spatial Nyquist frequency [Succo, Sommerfeldt, Gee, and Neilsen, Proc. Mtgs. Acoust. 30, 030015 (2018)]. The present work demonstrates that for narrowband sources with frequency content above the spatial Nyquist frequency, additive low-level broadband noise can improve intensity calculations. To be effective, the angular separation between the source and additive noise source should be less than 30°, while using phase unwrapping with a smaller angular separation will increase the usable bandwidth. The upper frequency limit for the bandwidth extension depends on angular separation, sound speed, and probe microphone spacing. Assuming the signal-to-additive-noise ratio (SNRa) is larger than 10 dB, the maximum level and angular bias errors incurred by the additive broadband noise beneath the frequency limit-or up until probe scattering effects must be taken into account-are less than 0.5 dB and 2.5°, respectively. Smaller angular separation yields smaller bias errors.
More Related Videos
09:57Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy
Published on: July 25, 2022
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Conjugate Addition (1,4-Addition) vs Direct Addition (1,2-Addition)
Conjugate addition results in a thermodynamically stable product. The reaction retains the stronger C=O bond at the expense of the weaker C=C π bond. The process is slow as the β carbon is less electrophilic than the carbonyl carbon.
Direct addition products are...
Calculating pH Changes in a Buffer Solution
Calculating the Equilibrium Constant
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation:
Calculating Standard Free Energy Changes
Conjugate Addition of Enolates: Michael Addition