Novel telemetric sensor capsule for EGD urgency triage: a feasibility study
Arthur Schmidt1,2, Melanie Zimmermann3, Markus Bauder2
1Department of Medicine II, Medical Center, University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.
Abstract:
Background and study aims Upper gastrointestinal bleeding (UGIB) is a frequent cause of hospitalization. Because of the lack of reliable noninvasive diagnostic tools, the decision to proceed with emergency endoscopy in these cases is made based on clinical parameters. A novel non-imaging telemetric real-time sensor capsule (HemoPill Acute, Ovesco Endoscopy AG) has shown promising results for noninvasive detection of UGIB in preclinical studies. Patients and methods We conducted a prospective non-randomized, single center, open-label study to investigate feasibility and safety of the novel sensor capsule in patients with symptoms of UGIB. The primary aim of the first clinical study was to investigate feasibility and safety of the device in a clinical setting. All patients underwent endoscopy within 12 hours after capsule ingestion. Sensor data from the capsule within 10 minutes after ingestion were compared with endoscopic findings. Results From April 2015 to February 2016, 30 consecutive patients with symptoms of acute UGIB were included; 27 were eligible for analysis. Capsule ingestion was well tolerated in all patients and there were no device-related adverse events. Endoscopy showed blood or hematin in the upper gastrointestinal tract of 10 of 27 patients; in 2 of 10 patients it was estimated to be more than 20 mL; in 4 of 8 patients it was between 5 and 20 mL and in 4 of 8 it was estimated to < 5 mL. The sensor capsule was positive in 2 of 2 patients (100 %) with > 20 mL of blood or hematin and in 1 of 8 patients (12.5 %) between 5 and 20 mL. All patients (17/17; 100 %) were correctly identified as non-bleeders. Conclusion Both device and procedure proved to be safe and feasible. Larger studies will be necessary to evaluate the role of the sensor capsule in risk stratification of patients with acute UGIB.
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules
Case Studies
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Longitudinal Studies
Observational Studies
There are three types of observational studies – Prospective, retrospective, and cross-sectional.
Prospective Study
Prospective studies, also known as longitudinal or cohort studies, are carried out by collecting future data from groups sharing similar characteristics. One...