Dermal Tattoo Biosensors for Colorimetric Metabolite Detection
Ali K Yetisen1, Rosalia Moreddu2, Sarah Seifi1
1Institute for Measurement Systems and Sensor Technology, Technical University of Munich, 80333, Munich, Germany.
Abstract:
Tattooing is a ubiquitous body modification involving the injection of ink and/or dye pigments into the dermis. Biosensors in the form of tattoos can be used to monitor metabolites in interstitial fluid. Here, minimally invasive, injectable dermal biosensors were developed for measuring pH, glucose, and albumin concentrations. The dermal pH sensor was based on methyl red, bromothymol blue, and phenolphthalein, which responded to a pH range from 5.0 to 9.0. The dermal glucose sensor consisted of glucose oxidase, 3,3',5,5'-tetramethylbenzidine, and peroxidase that detected concentrations up to 50.0 mmol L-1 . The dermal albumin sensor consisted of 3',3'',5',5''-tetrachlorophenol-3,4,5,6-tetrabromosulfophthalein to measure concentrations up to 5.0 g L-1 . The sensors were multiplexed in ex vivo skin tissue and quantitative readouts were obtained using a smartphone camera. These sensors can be used to manage of acid-base homeostasis, diabetes, and liver failure in point-of-care settings.
Related Concept Videos
Effect of Hepatic Disease on Pharmacokinetics: Active Drug, Metabolite and Fraction of Metabolized Drug
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...