Related Experiment Video
Updated: Jan 23, 2026

Transdermal Measurement of Glomerular Filtration Rate in Mice
Published on: October 21, 2018
Validation of Glomerular Filtration Rate Measurement with Blood Sampling from the Injection Site
Bethelhem W Mekonnen1, James M Warwick2, Jennifer L Holness2
1Nuclear Medicine Division, Department of Medical Imaging and Clinical Oncology, Stellenbosch University, Cape Town, South Africa bety192112@gmail.com.
Abstract:
Measurement of glomerular filtration rate (GFR) from the plasma clearance of a radionuclide-labeled tracer is reliable and accurate. However, to avoid contamination of the blood samples with radioactivity remaining at the injection site, venepuncture at 2 or more sites is required: one for tracer administration and the others for blood sampling. This requirement is uncomfortable for patients, particularly when venous access is difficult. The objective of this study was to validate the use of a single site of venous access in combination with injection site imaging, for GFR measurement. Methods: Twenty-two adults (≥18 y) who were referred for GFR determination were included prospectively. GFR was measured from the plasma clearance of 99mTc-diethylenetriaminepentaacetic acid according to international guidelines. After administration of the tracer through an intravenous cannula, a 60-s static image of the injection site was acquired. A second intravenous cannula was inserted into the contralateral arm. Venous blood samples were collected at 2, 3, and 4 h after administration of the radiotracer from both the injection site (experimental) and the contralateral arm (conventional). GFR was calculated using slope-intercept and single-sample methods. The median conventional and experimental plasma counts (decay- and background-corrected) were compared for the 2-, 3-, and 4-h venous samples. Conventional and experimental GFRs were then compared, with a more than 10% difference between conventional and experimental GFRs being regarded as significant. Results: Four individuals had visible residual activity at the injection site. The median 2-h counts differed significantly between the conventional and experimental sampling sites (P = 0.007), whereas no significant difference was found at 3 or 4 h. When there was a clear injection site image, the difference between the experimental and conventional GFRs was more than 10% in 1 case for single-sample GFR but less than 8% in all cases for slope-intercept GFR. Conclusion: In cases with clear injection site images, slope-intercept GFR calculated after injection site blood sampling showed no clinically significant difference from conventional contralateral-arm sampling.
Related Concept Videos
Glomerular Filtration Rate and its Regulation
GFR regulation involves two primary intrinsic controls: the myogenic and tubuloglomerular feedback mechanisms.
The myogenic...
Glomerular Filtration
Components of the Filtration Membrane
The filtration process involves three key layers: the glomerular endothelial cells, the basement membrane, and the podocyte-formed filtration slits.
Glomerular Filtration: Net Filtration Pressure
GBHP, with an average value of 55 mmHg, promotes filtration by pushing water and solutes through the filtration membrane. This is balanced by two opposing forces: CHP, a "back pressure" exerted against the filtration membrane by fluid already in the capsular space and renal...
Physiology of the Genitourinary System I: Renal Blood Flow and Glomerular Filtration
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles....
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration

