Related Experiment Video
Updated: Jan 23, 2026

In Vivo Gene Transfer to the Rabbit Common Carotid Artery Endothelium
Published on: May 6, 2018
Short non-patch arteriotomy in carotid endarterectomy
Marco Leopardi1, Angelica Dante2, Giorgio Sbenaglia2
1Department of Vascular Surgery, San Salvatore Hospital, University of L'Aquila, L'Aquila, Italy - marcoleopardi@gmail.com.
The short non-patch carotid endarterectomy technique offers favorable midterm outcomes. This method demonstrates low rates of stroke, restenosis, and cranial nerve injuries in patients with carotid artery stenosis.
Area of Science:
- Vascular Surgery
- Cerebrovascular Disease
Background:
- Carotid endarterectomy is a common procedure for carotid artery stenosis.
- Various surgical techniques exist, with ongoing evaluation of their efficacy and safety.
Purpose of the Study:
- To describe and evaluate the midterm results of a specific short non-patch arteriotomy technique for carotid endarterectomy.
- To assess the safety and effectiveness of this technique in managing carotid artery stenosis.
Main Methods:
- Analysis of patients undergoing carotid endarterectomy using the short non-patch arteriotomy technique.
- The technique involves a short longitudinal arteriotomy, blunt spatula plaque removal, and semi-eversion in the internal carotid artery.
- Outcomes assessed include mortality, stroke, restenosis, and local complications.
Main Results:
- 436 carotid endarterectomies were performed using the short non-patch technique between 2011-2016.
- In-hospital stroke rate was 0.7%, with complete recovery in all cases.
- Two-year restenosis rate was 1.4%, managed with carotid stenting.
Conclusions:
- The short non-patch carotid endarterectomy technique is associated with low midterm rates of stroke, restenosis, and cranial nerve injuries.
- This technique presents a viable alternative compared to other reported surgical series.
More Related Videos
Related Concept Videos
Long-patch Base Excision Repair
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Power System Three-Phase Short Circuits
Short-distance Transport of Resources
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Anatomy of the Circulatory System

