A Microwave-Induced Thermoacoustic Imaging System With Non-Contact Ultrasound Detection
Abstract:
Portable and easy-to-use imaging systems are in high demand for medical, security screening, nondestructive testing, and sensing applications. We present a new microwave-induced thermoacoustic imaging system with non-contact, airborne ultrasound (US) detection. In this system, a 2.7 GHz microwave excitation causes differential heating at interfaces with dielectric contrast, and the resulting US signal via the thermoacoustic effect travels out of the sample to the detector in air at a standoff. The 65 dB interface loss due to the impedance mismatch at the air-sample boundary is overcome with high-sensitivity capacitive micromachined ultrasonic transducers with minimum detectable pressures (MDPs) as low as 278 μ Pa rms and we explore two different designs-one operating at a center frequency of 71 kHz and another at a center frequency of 910 kHz. We further demonstrate that the air-sample interface presents a tradeoff with the advantage of improved resolution, as the change in wave velocity at the interface creates a strong focusing effect alongside the attenuation, resulting in axial resolutions more than 10× smaller than that predicted by the traditional speed/bandwidth limit. A piecewise synthetic aperture radar (SAR) algorithm modified for US imaging and enhanced with signal processing techniques is used for image reconstruction, resulting in mm-scale lateral and axial image resolution. Finally, measurements are conducted to verify simulations and demonstrate successful system performance.
Related Concept Videos
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: