Establishment of relationships between native and inhalation device specific spirometric parameters as a step towards
Árpád Farkas1, Annamária Szipőcs2, Alpár Horváth3
1Centre for Energy Research, Hungarian Academy of Sciences, Konkoly-Thege Miklós út 29-33, 1121, Budapest, Hungary.
Introduction:
Drug emission from DPIs is dependent on the inspiratory flow parameters through them, which are not directly measured by standard spirometry. Their estimation based on native spirometric data could help in choosing the appropriate device and optimizing the drug deposition.
Objectives:
The aim of this study was to survey patient preferences and to find correlations between breathing parameters of COPD patients through DPI devices and their baseline spirometric data, age, gender, disease severity and anthropometric characteristics. Another objective was to establish relationships between peak inspiratory flows (PIFdev) through Breezhaler®, Genuair® and Turbuhaler® inhalers and their determinants.
Methods:
Breathing parameters of 49 patients with previously diagnosed COPD and currently using one of the above inhalers were recorded by normal spirometry and while inhaling through the selected DPIs. Statistical analysis of the measured data was completed. All specific data are provided as (mean ± standard deviation).
Results:
More than 60% of the patients stated that their current device is the easiest to use. The means of the measured PIFdev values were 91.4 L/min, 77.1 L/min and 77.5 L/min for Breezhaler®, Genuair®, and Turbuhaler®, respectively. PIFdev values were significantly higher for males than for females, but differences upon age, BMI and disease severity group were not significant (at p = 0.05). Peak inspiratory flows through the inhalers (PIFdev) correlated best with their native spirometric counterparts (PIF) and linear PIFdev-PIF relationships could be determined (Breezhaler®: r = 0.60, p = 0.002, Genuair®: r = 0.55, p = 0.001, Turbuhaler®: r = 0.57, p = 0.002). Physical background of the deduced equations was also provided.
Conclusions:
Present correlations may be used to assess the success of inhalation of COPD patients through the studied devices and to choose the appropriate device for each patient. As a consequence, the amount of the drug emitted by the device can be optimized, the deposition efficiency within the lungs increased and the related therapeutic effect improved.
Related Concept Videos
Inhaled Medications
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Dose-Response Relationship: Selectivity and Specificity
Inhalational Anesthetics: Overview
Antiasthma Drugs: Inhaled Corticosteroids and Glucocorticoids
ICS work through a multifaceted mechanism of action. They suppress the inflammatory response caused by the proliferation of TH cells. They also reduce the transcription of the IL-2 gene, which is involved in the...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...