Comparison of Volar and Dorsal Approach for PIP Arthroplasty
Geneva V Tranchida1, Scott T Allen1, Susan M Moen2
1University of Minnesota, Minneapolis, USA.
Abstract:
Background: No consensus exists about whether a volar approach (VA) or dorsal approach (DA) for proximal interphalangeal (PIP) arthroplasty yields better results. Previously reported range of motion (ROM) and complications vary from study to study. This retrospective review compared the ROM and complication rates of VA and DA approaches to PIP arthroplasty. Methods: The study included 66 adults (88 digits) who underwent PIP arthroplasty from 2000 to 2015, with minimum 30-day follow-up. Demographic data, surgical approach, pre- and post-operative ROM, duration of immobilization, timing and duration of hand therapy (occupational therapy [OT]), and major and minor complications were recorded. We compared mean change in ROM, postoperative ROM, and complication rates, and examined the association of duration of immobilization and time to OT initiation with postoperative ROM. Results: While there was no difference in postoperative ROM between volar and dorsal groups (56° and 54°, respectively, P > .05), there was a greater gain in ROM in the DA group (25° vs 2.7°, P = .017). There was no statistically significant difference in overall incidence of complications (VA: 37.8%, DA: 30.3%; P > .05) or revision surgery (VA: 15.6%, DA: 17.1%; P > .05). There were no differences in duration of immobilization, time to OT initiation, or number of OT sessions between the two groups, and none of these correlated with postoperative ROM. Conclusions: We identified no statistical difference in mean postoperative ROM, incidence of complications or revision surgery between volar and dorsal approaches for PIP arthroplasty.
Related Concept Videos
Phosphoinositides and PIPs
Different phosphoinositides are synthesized and recruited on the cytosolic face of the plasma membrane. The localization of specific phosphoinositides concentrated in separate membrane...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits