Clinical Assessment of Spatiotemporal Gait Parameters in Patients and Older Adults
Published on: November 7, 2014
Agreement between spatiotemporal parameters from a photoelectric system with different filter settings and high-speed
Felipe García-Pinillos1, Pedro Á Latorre-Román2, Rodrigo Ramirez-Campillo3
1Department of Physical Education, Sports and Recreation, Universidad de La Frontera, Temuco, Chile.
Abstract:
The aim of this study was to determine the level of agreement between spatiotemporal gait characteristics from a photoelectric system with different filter settings and high-speed video analysis during running on a treadmill at comfortable velocity. Forty-nine runners performed a running protocol on a treadmill at comfortable velocity. Two systems were used to determine spatiotemporal parameters (i.e. contact time [CT], flight time [FT], step frequency [SF] and step length [SL]) during running: OptoGait system and high-speed video analysis at 1000 Hz. The collected data was re-filtered in the OptoGait software by using nine different settings (i.e. 0_0, 1_1, 2_2, 3_3, 3_4, 4_4, 4_5, 5_4 and 5_5), and compared to those obtained through video analysis. The Pearson correlation analysis revealed very large correlations (r > 0.9, p < 0.001) in CT, FT, SF and SL between both systems, regardless of the OptoGait's filter settings. The ICC reported an almost perfect association (ICC > 0.9) for both SL and SF regardless of the filter setting. However, large variations between filter settings according to the data from video analysis were reported in CT and FT (0_0, 1_1 and 2_2 filter settings obtained an association ICC > 0.9, whereas other filters obtained lower ICCs). Bland-Altman plots revealed small bias and error and no presence of heteroscedasticity of error for 1_1 setting. In conclusion, the filter setting for the OptoGait system should be considered to minimize the bias and error of spatiotemporal parameters measurement. For running on a treadmill, the 1_1 filter setting is recommended if gait parameters are to be compared to a high-speed video analysis (1000 Hz).
More Related Videos
07:44Evaluation of Patients' Posture and Gait Profile After Lumbar Fusion Surgery by Video Rasterstereography and Treadmill Gait Analysis
Published on: March 23, 2019
08:26Comparative Analysis of Lower Limb Kinematics between the Initial and Terminal Phase of 5km Treadmill Running
Published on: July 17, 2020
Related Concept Videos
Photoelectric Effect
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's...
Actin Treadmilling
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Wald-Wolfowitz Runs Test II
For binary data, runs are identified using symbols such as + and −, or equivalently, 1s and 0s. In...