Heinz body-related interference with leukocyte and erythrocyte variables obtained by an automated hematology analyzer

Francesco Dondi1, Kateryna Vasylyeva1, Federica Serafini1

  • 1Department of Veterinary Medical Sciences, Alma Mater Studiorum-University of Bologna, Ozzano dell'Emilia, Bologna.

Heinz bodies (HBs) are known to interfere with automated hematology in cats, particularly with the white blood cell (WBC) count. We evaluated the influence of feline HBs on the complete blood count (CBC) results obtained using a flow cytometry-based analyzer. We retrospectively selected cats with circulating HBs and reviewed the results of their CBCs, including red blood cell (RBC) indices, basophil/lobularity (Baso) WBC count (WBCB), peroxidase (Perox) WBC count (WBCP), and cytograms. Based on the presence or absence of HB-related artifacts in their Baso cytogram, cats were grouped into Baso-HBs and HBs groups, respectively, for comparison. The WBCB and WBCP were compared to manual counts of WBCs carried out on blood smears at 400× (MC-WBC). We included 32 cats in our study: 9 of 32 were in the Baso-HBs group, and 23 of 32 were in the HBs group. Baso-HBs cats had a significantly increased HB percentage (p < 0.001), WBCB (p < 0.001), difference between WBCB and WBCP (p < 0.001), lymphocyte count (p < 0.001), mean corpuscular hemoglobin concentration (p < 0.001), and difference between calculated and measured erythrocyte hemoglobin concentrations (p < 0.001) compared to HBs cats. In Baso-HBs cats, the WBCB was significantly higher than the WBCP (p = 0.02); no significant difference was detected between the WBCP and the MC-WBC (p = 0.88). Evaluation of automated CBC results raised the suspicion of HB-related interference when using a hematology analyzer in cats; hence, blood smear examination remains essential in routine practice.

Related Concept Videos

Interference and Diffraction02:18

Interference and Diffraction

Interference is a characteristic phenomenon exhibited by waves. When two electromagnetic waves interact with their peaks and troughs coinciding, a resulting wave with enhanced amplitude is produced. This is known as constructive interference. In this case, the two waves interacting are in phase with each other.
51.9K
RNA Interference01:23

RNA Interference

RNA interference (RNAi) is a process in which a small non-coding RNA molecule blocks the post-transcriptional expression of a gene by binding to its messenger RNA (mRNA) and preventing the protein from being translated.
This process occurs naturally in cells, often through the activity of genomically-encoded microRNAs. Researchers can take advantage of this mechanism by introducing synthetic RNAs to deactivate specific genes for research or therapeutic purposes. For example, RNAi could be used...
27.9K
Lifecycle of Erythrocytes01:22

Lifecycle of Erythrocytes

Erythrocytes, also known as red blood cells, constantly move through blood capillaries. As a result, they damage their plasma membrane due to the continuous friction. Typically, after 100 to 120 days, erythrocytes become rigid and fragile as they wear out. As they pass through small vessels in the spleen and liver, they can get trapped and break apart into fragments.
The resident phagocytic macrophages deal with these damaged cells by engulfing them and separating their globin and heme groups....
4.7K
Disorders of Erythrocytes01:27

Disorders of Erythrocytes

Disorders of erythrocytes, or red blood cells (RBCs), include a range of conditions affecting their number, shape, or function.
Erythrocyte disorders can be broadly categorized into two main types: anemic and polycythemic conditions.
A low oxygen-carrying capacity of the blood due to the loss, lower production, or destruction of erythrocytes is termed anemia. Hemorrhagic anemia, for example, occurs when bleeding from an external wound or internal ulcer reduces erythrocyte counts.
On the other...
2.1K
Structure and Function of Erythrocytes01:29

Structure and Function of Erythrocytes

There are between 4.2 and 6 million erythrocytes, also known as red blood cells, in every microliter of blood. These cells are small, flattened biconcave discs with centers that are depressed.
The erythrocyte plasma membrane is associated with proteins such as spectrin, which forms a flexible cytoplasmic meshwork. This meshwork allows erythrocytes to twist, turn, become cup-shaped, and regain their biconcave shape as they pass through narrow capillaries. Additionally, erythrocytes can form...
5.3K
Variables Affecting Phosphorescence and Fluorescence01:26

Variables Affecting Phosphorescence and Fluorescence

Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
1.3K