Detecting creatine excreted in the urine of swimming athletes by means of Raman spectroscopy
Related Experiment Video
Updated: Jan 22, 2026

Surface Enhanced Raman Spectroscopy Detection of Biomolecules Using EBL Fabricated Nanostructured Substrates
Published on: March 20, 2015
Letícia Parada Moreira1, Débora Dias Ferraretto Moura Rocco1, Alexandre Galvão da Silva1
1Universidade Santa Cecília - UNISANTA, Rua Oswaldo Cruz, 277, Santos, SP, 11045-907, Brazil.
Abstract:
High-level sport requires analysis of athletes' metabolic conditions in order to improve the training. Raman spectroscopy can be used to assess urinary composition advantageously when compared to conventional methods of urinalysis. In this work, Raman spectroscopy has been employed to detect creatine in urine of professional swimmers before and after training compared to sedentaries. It has been collected urine samples from five swimmers before and immediately after 150 min of swimming and submitted to Raman spectroscopy (830 nm excitation, 350 mW laser power, 20 s integration time) and compared to the urine from a control group (14 sedentary subjects). The Raman spectra of urine from four swimmers after training showed peaks related to creatine at 829, 915, 1049, and 1397 cm-1, besides peaks referred to urea, creatinine, ketone bodies, and phosphate. A spectral model estimated the concentration of creatine to be from 0.26 to 0.72 g/dL in the urine of these athletes. The presence of this metabolic biomarker in the urine of some swimmers suggests a metabolic profile influenced by the diet, supplementation, individual metabolism, and the self-response to the training. Raman spectroscopy allows a rapid and reliable detection of creatine excreted in the urine of swimming athletes, which may be used to adjust the nutrition/supplementation of each individual as well as the individual response and energy consumption depending on the type and duration of the training.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Filtration and Urine Formation
Renal Drug Excretion: Effect of Urine pH, Flow Rate, and Drug pKa
The pKa of a...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Urine Studies II: Urine Culture and Sensitivity Test
What Are Osmoregulation and Excretion?

