Monitoring Magnesium Stearate Blending in a V-Blender Through Passive Vibration Measurements
Austin Cameron1, Lauren Briens2
1Faculty of Engineering, Western University, London, Ontario, Canada.
Abstract:
Process analytical technologies are implemented within the pharmaceutical manufacturing process to rectify issues associated with current sampling methods. These include inline monitoring methods such as passive vibration measurements which are non-intrusive and less costly to other methods. In the final mixing stage of the tablet manufacturing process, a lubricant is added to ensure the mixture is ejected from the tablet die cleanly. To monitor this process, an accelerometer was attached to the lid of the V-blender loaded with various particles and magnesium stearate. At a fixed fill level, the lubricant concentration and particle mass were varied to investigate the effects of changes in process parameters on the signal vibrations measured by the sensor, the coefficient of restitution, and the flowability. It was found that measured vibrations from stress waves propagated upon collisions of the particles with the V-shell respond to and can distinguish differences in particles. As well, the magnesium stearate layer around particles alters energy dissipation and subsequently the measured vibrations. A mixing endpoint of uniform distribution of magnesium stearate with primary particles can be identified from vibrations measured by an accelerometer attached to the lid of the V-blender. The flowability change was considered negligible in the particles due to their physical morphology. These findings indicate that passive vibration measurements can be a viable, non-intrusive monitoring method while providing insight into V-blender mixing behaviors as well as improving process efficiency.
Related Concept Videos
Vibrating Concrete
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Passive Diffusion: Overview and Kinetics
When administered orally, drugs establish a substantial concentration gradient between the gastrointestinal (GI) lumen and the bloodstream, expediting...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations