Related Experiment Video
Updated: Jan 21, 2026

An In Vitro Model to Study the Effect of 5-Aminolevulinic Acid-mediated Photodynamic Therapy on Staphylococcus aureus Biofilm
Published on: April 16, 2018
Is the Intensity of 5-Aminolevulinic Acid-Derived Fluorescence Related to the Light Source?
Marcel A Kamp1, Johannes Knipps1, Lisa Margarete Neumann1
1Department of Neurosurgery, Medical Faculty, Heinrich-Heine-University, Düsseldorf, Düsseldorf, Germany.
Objective:
With the introduction of the 5-aminolevulinic acid (5-ALA) technique, surgical neuro-oncology has made a major advance. 5-ALA fluorescence-guided resection of malignant glioma results in more complete surgical resections and subsequently prolonged survival. However, it remains uncertain how light intensities of the blue light source and 5-ALA-derived fluorescence intensities of the illuminated tissue are connected. The aim of the present study was to compare light intensities of different blue light sources and protoporphyrin (PpIX) fluorescence intensities of PpIX solutions with defined concentrations after illumination with different light sources.
Material And Methods:
The light spectrum of 7 different blue light sources and the fluorescence intensity of 2 PpIX solutions (0.15 μg/mL and 5 μg/mL) were quantified after illumination. We compared the Zeiss OPMI Pentero microscope, the Zeiss OPMI Pentero 900 microscope, the Leica M530 OH6 microscope, an endoscope equipped with the 5-ALA technique, a mini-spectrometer equipped with a multi-channel light-emitting diode (LED) source emitting monochromatic light, a modified commercially available LED head lamp, and a commercially available unmodified UV-LED lamp. PpIX fluorescence was quantified in a standardized setup using a mini-spectrometer.
Results:
Maximum light intensities of the evaluated light sources were reached at different wavelengths. All tested devices were able to detect PpIX-induced fluorescence. However, the intensity of PpIX fluorescence of the differently concentrated PpIX solutions (0.15 μg/mL and 5 μg/mL) was significantly dependent on the light source used.
Conclusions:
Intensity of the 5-ALA-derived fluorescence is related to the light source used.
Related Concept Videos
Acidity and Basicity of Carboxylic Acid Derivatives
The relative acidic strength of the derivatives can be explained based on the extent of resonance stabilization of the conjugate base. The...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Structures of Carboxylic Acid Derivatives
Carboxylic acid derivatives contain an acyl group attached to a heteroatom such as chlorine, oxygen, or nitrogen. The carbonyl carbon and oxygen are both sp2-hybridized with an unhybridized p orbital.
The three sp2 orbitals of the carbonyl carbon form three σ bonds, one each with the carbonyl oxygen, the α carbon, and the heteroatom, whereas the other two sp2 orbitals of the carbonyl oxygen are occupied by the lone pairs. Further, the unhybridized p...
Spectroscopy of Carboxylic Acid Derivatives
Nomenclature of Carboxylic Acid Derivatives: Acid Halides, Esters, and Acid Anhydrides
The IUPAC and common names of acid halides are derived from the corresponding carboxylic acids, by changing “ic acid” to “yl halide.” For example, as shown below, the IUPAC name ethanoyl chloride is derived from ethanoic acid, and the common name, acetyl chloride, is obtained from acetic acid.
Carboxylic Acid Derivatives: Overview

