Related Experiment Video
Updated: Jan 21, 2026

Exfoliation and Analysis of Large-area, Air-Sensitive Two-Dimensional Materials
Published on: January 5, 2019
Linear Dimensional Changes of Five Interocclusal Recording Materials When Immersed in Two Disinfectants for Different
Rajanna Kv Patel1, Sushant A Pai1, Tejavathi Nagaraj2
1Department of Prosthodontics, Sri Rajiv Gandhi College of Dental Sciences and Hospital, Bengaluru, Karnataka, India.
Bisacryl bite registration material showed no dimensional changes after immersion in disinfectant solutions, making it the most accurate option compared to wax, zinc oxide eugenol, polyether, and polyvinyl siloxane.
Area of Science:
- Dental materials science
- Disinfection protocols
Background:
- Accurate interocclusal records are crucial for dental prosthetics.
- Disinfectant solutions are used to prevent cross-contamination.
- Dimensional stability of recording media after disinfection is a concern.
Purpose of the Study:
- To compare the linear dimensional changes of five interocclusal recording media.
- To evaluate the effect of disinfectant immersion time on dimensional stability.
Main Methods:
- Five material types were tested: wax, zinc oxide eugenol, polyether, polyvinyl siloxane, and bisacryl.
- Samples were immersed in 2% glutaraldehyde and 0.5% sodium hypochlorite for 30 and 60 minutes.
- Linear dimensional changes were measured using a stereomicroscope and compared to a control group.
Main Results:
- Bisacryl exhibited the least linear dimensional change among all tested materials.
- Other materials showed varying degrees of dimensional alteration after disinfectant immersion.
Conclusions:
- Bisacryl (Luxabite) demonstrated superior dimensional stability, with no measurable changes.
- Bisacryl is recommended as the most accurate interocclusal recording material following disinfection procedures.
Related Concept Videos
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
Voltammetric Techniques: Linear-Scan (E vs Time)
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
Confidence Intervals
A...

