Related Experiment Video
Updated: Jan 21, 2026

Rapid and Specific Detection of Acinetobacter baumannii Infections Using a Recombinase Polymerase Amplification/Cas12a-based System
Published on: April 25, 2025
FALSE POSITIVE PHENOTYPIC DETECTION OF METALLO-BETA-LACTAMASES IN ACINETOBACTER BAUMANNII
Branka Bedenić1, Ranko Ladavac1, Mirna Vranić-Ladavac1
11Department of Microbiology, School of Medicine, University of Zagreb, Zagreb, Croatia; 2Department of Clinical and Molecular Microbiology, Zagreb University Hospital Centre, Zagreb, Croatia; 3Department of Nephrology, Pula General Hospital, Pula, Croatia; 4Department of Microbiology, Public Health Institute of Istria County, Pula, Croatia; 5Department of Clinical Immunology, Pulmonology and Rheumatology, Sestre milosrdnice University Hospital Centre, Zagreb, Croatia; 6Department of Anesthesiology, Zagreb University Hospital Centre, Zagreb, Croatia; 7Department of Internal Medicine, Zagreb University Hospital Centre, Zagreb, Croatia; 8Zagreb Secondary Medical School, Zagreb, Croatia.
Abstract:
Phenotypic detection of metallo-β-lactamases (MBLs) in Acinetobacter (A.) baumannii is a serious challenge to clinical microbiologists. MBLs are inhibited by metal chelators such as ethylenediaminetetraacetic acid) (EDTA). Production of MBLs cannot be recognized based on resistance phenotype. Therefore, phenotypic tests using EDTA are recommended. The aim of this study was to investigate the sensitivity and specificity of inhibitor based tests (EDTA) for detection of MBL. A total of 172 A. baumannii strains (123 carbapenemase positive and 49 carbapenemase negative) were analyzed. Phenotypic detection of MBLs was performed by the combined disk test with EDTA (CDT-EDTA) and EPI-dilution test (EPI-DT). Both tests were positive in all 11 isolates possessing VIM-1 MBL, showing 100% sensitivity. However, false positive results were observed in strains with class D carbapenemases using both tests, i.e. all OXA-23 and OXA-24/40 producing organisms and most OXA-58 positive strains (77% with CDT-EDTA vs. 65% with EPI-DT). False positive results can occur because oxacillinases are converted to a less active state in the presence of EDTA, leading to augmentation of the inhibition zone around the carbapenem disk or reduction of carbapenem minimum inhibitory concentrations. This study showed high sensitivity but low specificity of phenotypic methods in the detection of MBLs.
More Related Videos
Related Concept Videos
False Memories
One primary source of false memories is misattribution, where individuals incorrectly associate external information...
Position-effect Variegation
Position and Displacement
Serial Position Effect
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Position Vectors
For instance, we want to locate a point P(x, y, z) relative to the origin of coordinates O. In that case, we can define a position...

