Comparison of two L shaped Plate on Plate Versus Single Conventional L Miniplate in Fixation of Subcondylar
Biju Pappachan1, Raghav Agrawal2
1GDC Raipur, Lane-6, New Shanti Nagar, Raipur, Chhattisgarh India.
Aim:
To compare and evaluate treatment outcome and postoperative complications in subcondylar fractures of mandible-single L shape plate versus two L shape plate-using plate on plate technique.
Materials And Methods:
The clinical trial had a total of ten patients (ten unilateral subcondylar fracture sites), which were divided randomly into two groups of five each. Group I patients underwent open reduction and internal fixation with single L shaped miniplate and Group II ORIF was done with two L shaped miniplates by plate on plate technique.
Results:
Both the groups showed comparable results in terms of postoperative complications. Few cases in Group I presented with minor occlusal discrepancy which was easily corrected with transitional inter-maxillary fixation(IMF) for 1 week, and none of the Group II cases required postoperative IMF, but stability in Group II was better than Group I.
Conclusion:
The results of this trial suggested that the treatment of mandibular condylar fractures with 2 (2-D) plates placed one over the other is better suited than conventionally practiced single-plate fixation. Increased 3-dimensional stability, low morbidity and infection rates are the advantages offered by 2-plate technique of ours.
More Related Videos
04:13Less-Invasive Technique for Non-stabilized Mandibular Fracture in Mouse Models
Published on: September 27, 2024
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Fluid Pressure over Curved Plate of Constant Width
Steady, Laminar Flow Between Parallel Plates
Fluid Pressure over Flat Plate of Constant Width
The resultant force...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...