Thermal Measurement Techniques in Analytical Microfluidic Devices
Published on: June 3, 2015
Development of a micro-distillation microfluidic paper-based analytical device as a screening tool for total ammonia
Jonathan J Peters1, M Inês G S Almeida1, Lenka O'Connor Šraj1
1School of Chemistry, The University of Melbourne, Victoria, 3010, Australia.
Abstract:
An easy-to-use, portable 3D microfluidic paper-based analytical device (μPAD) for the determination of total ammonia (i.e., ammonia + ammonium) in freshwaters is described. It consists of two layers of paper patterned with hydrophilic circular zones, one impregnated with sodium hydroxide (sample zone) and another (detection zone) with an acid-base indicator (nitrazine yellow (NY) or bromothymol blue (BTB)), separated by a μ-distillation chamber. Ammonium ions present in the water sample are converted into ammonia gas by reaction with sodium hydroxide in the sample zone. Ammonia then diffuses through a headspace and reacts with an acid-base indicator in the detection zone, the reflectance of which can be related to the total ammonia concentration. The analytical signal at 7.8 mg L-1 offered by the μ-distillation chamber-based μPAD is more than double of that obtained using a gas-permeable membrane. The proposed μPAD is characterised by a limit of detection of 0.32 or 0.47 mg N L-1 and working concentration ranges of 0.5-3.0 mg N L-1 or 2.0-10 mg N L-1 when using NY or BTB indicators, respectively. This is the first μPAD whose working range covers almost the entire trigger value range (0.32-2.3 mg N L-1) for ammonia nitrogen in freshwater systems which makes it suitable as a field screening tool for ammonia in freshwaters. An inter- and intra-device repeatability of 7.6% and 9.0%, respectively, has been achieved for the NY-based μPAD (3 mg N L-1) and 13 and 2.5% (8 mg N L-1) for the BTB-based μPAD. The NY-based μPAD is stable under vacuum for at least 12 days at room temperature, and 56 days if stored in a freezer (≤-20 °C).
Related Concept Videos
Development of Analytical Methods
Distillation: Vapor–Liquid Equilibria
Preparation of Amines: Alkylation of Ammonia and Amines
Each alkylation step makes the nitrogen center more nucleophilic, which triggers successive alkylations until a quaternary ammonium salt is formed. Considering...
Analyte Adsorption and Distribution
Jung's Analytical Theory
Graphical and Analytic Representation of Sinusoids
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...