Published on: July 17, 2017
Determination of the superficial citral content on microparticles: An application of NIR spectroscopy coupled with
Ives Yoplac1,2, Himer Avila-George3, Luis Vargas4
1Facultad de Ingeniería Zootecnista, Agronegocios y Biotecnología, Universidad Nacional Toribio Rodríguez de Mendoza de Amazonas, Chachapoyas, Peru.
Abstract:
This work evaluates near-infrared (NIR) spectroscopy coupled with chemometric tools for determining the superficial content of citral ( ) on microparticles. To perform this evaluation, using spray drying, citral was encapsulated in a matrix of dextrin using twelve combinations of citral:dextrin ratios (CDR) and inlet air temperatures (IAT). From each treatment, six samples were extracted, and their and NIR absorption spectral profiles were measured. Then, the spectral profiles, pretreated and randomly divided into modeling and validation datasets, were used to build the following prediction models: principal component analysis-multilinear regression (PCA-MLR), principal component analysis-artificial neural network (PCA-ANN), partial least squares regression (PLSR) and an artificial neural network (ANN). During the validation stage, the models showed values from 0.73 to 0.96 and a root mean squared error (RMSE) range of [0.061-0.140]. Moreover, when the models were compared, the full and optimized ANN models showed the best fits. According to this study, NIR coupled with chemometric tools has the potential for application in determining on microparticles, particularly when using ANN models.
Related Concept Videos
NMR Spectroscopy: Spin–Spin Coupling
Applications of IR Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...