Development and Performance of Electronic Pediatric Risk of Mortality and Pediatric Logistic Organ Dysfunction-2
Christopher M Horvat1,2,3, Henry Ogoe3, Sajel Kantawala1,3
1Department of Critical Care Medicine, University of Pittsburgh School of Medicine, Pittsburgh, PA.
Insights
Electronic pediatric intensive care unit (PICU) scores, including the Pediatric Risk of Mortality-IV and Pediatric Logistic Organ Dysfunction-2, demonstrate strong predictive validity for hospital mortality. These validated scores can enhance quality improvement and research in PICUs.
Area of Science:
- Pediatric critical care medicine
- Health informatics
- Clinical outcomes research
Background:
- Pediatric Risk of Mortality-IV (PRISM-IV) and Pediatric Logistic Organ Dysfunction-2 (PELOD-2) scores are crucial for assessing pediatric intensive care unit (PICU) patient severity.
- Electronic health records (EHRs) offer a potential platform for deriving these scores efficiently.
- Validating electronic versions of these scores is essential for their reliable application in clinical practice and research.
Purpose of the Study:
- To develop and evaluate the performance of electronic versions of the PRISM-IV and PELOD-2 scores.
- To assess the predictive validity of these electronic scores for hospital mortality.
- To determine the accuracy and calibration of electronically derived scores.
Main Methods:
- A retrospective cohort study was conducted using structured EHR data from a quaternary PICU.
- The study included 21,335 PICU encounters between January 1, 2009, and December 31, 2017.
- Predictive validity was assessed using discrimination (AUC-ROC, AUC-PR) and calibration (Hosmer-Lemeshow test, standardized mortality ratio) after recalibration.
Main Results:
- Electronic PRISM-IV and PELOD-2 scores showed strong agreement with prospectively calculated data.
- Uncalibrated AUC-ROC values were 0.87 for electronic PRISM-IV and 0.96 for electronic PELOD-2.
- Recalibrated models demonstrated acceptable goodness-of-fit, indicating reliable predictive performance.
Conclusions:
- Electronically derived PRISM-IV and PELOD-2 scores exhibit excellent predictive validity for hospital mortality in the PICU.
- These validated electronic scores can facilitate performance improvement initiatives and interinstitutional research.
- The use of EHR data for acuity scoring offers a scalable strategy for PICU outcome comparisons.
Objectives:
Develop and test the performance of electronic version of the Children's Hospital of Pittsburgh Pediatric Risk of Mortality-IV and electronic version of the Children's Hospital of Pittsburgh Pediatric Logistic Organ Dysfunction-2 scores.
Design:
Retrospective, single-center cohort derived from structured electronic health record data.
Setting:
Large, quaternary PICU at a freestanding, university-affiliated children's hospital.
Patients:
All encounters with a PICU admission between January 1, 2009, and December 31, 2017, identified using electronic definitions of inpatient encounter.
Interventions:
None.
Measurements And Main Results:
The main outcome was predictive validity of each score for hospital mortality, assessed as model discrimination and calibration. Discrimination was examined with the area under the receiver operating characteristics curve and the area under the precision-recall curve. Calibration was assessed with the Hosmer-Lemeshow goodness of fit test and calculation of a standardized mortality ratio. Models were recalibrated with new regression coefficients in a training subset of 75% of encounters selected randomly from all years of the cohort and the calibrated models were tested in the remaining 25% of the cohort. Content validity was assessed by examining correlation between electronic versions of the scores and prospectively calculated data (electronic version of the Children's Hospital of Pittsburgh Pediatric Risk of Mortality-IV) and an alternative informatics approach (Children's Hospital of Pittsburgh Pediatric Logistic Organ Dysfunction-2 score). The cohort included 21,335 encounters. Correlation coefficients indicated strong agreement between different methods of score calculation. Uncalibrated area under the receiver operating characteristics curves were 0.96 (95% CI, 0.95-0.97) for electronic version of the Children's Hospital of Pittsburgh Pediatric Logistic Organ Dysfunction-2 score and 0.87 (95% CI, 0.85-0.89) for electronic version of the Children's Hospital of Pittsburgh Pediatric Risk of Mortality-IV for inpatient mortality. The uncalibrated electronic version of the Children's Hospital of Pittsburgh Pediatric Risk of Mortality-IV standardized mortality ratio was 0.63 (0.59-0.66), demonstrating strong agreement with previous, prospective evaluation at the study center. The uncalibrated electronic version of the Children's Hospital of Pittsburgh Pediatric Logistic Organ Dysfunction-2 score standardized mortality ratio was 0.20 (0.18-0.21). All models required recalibrating (all Hosmer-Lemeshow goodness-of-fit, p < 0.001) and subsequently demonstrated acceptable goodness-of-fit when examined in a test subset (n = 5,334) of the cohort.
Conclusions:
Electronically derived intensive care acuity scores demonstrate very good to excellent discrimination and can be calibrated to institutional outcomes. This approach can facilitate both performance improvement and research initiatives and may offer a scalable strategy for comparison of interinstitutional PICU outcomes.
Related Concept Videos
Pharmacokinetics in Pediatric Patients: Drug Excretion
Pharmacokinetics in Pediatric Patients: Drug Distribution
Pharmacokinetics in Pediatric Patients: Drug Metabolism
Pharmacokinetics in Pediatric Patients: Overview and Drug Absorption
Piaget's Stage 2 of Cognitive Development
Development of the Sexual Organs in the Embryo and Fetus
Near the gonadal ridges, two duct systems are present: the mesonephric ducts (Wolffian ducts) and paramesonephric ducts (Müllerian ducts). These ducts form the basis for the...