Related Experiment Video
Updated: Jan 20, 2026

Exfoliation and Analysis of Large-area, Air-Sensitive Two-Dimensional Materials
Published on: January 5, 2019
Chemically exfoliated highly conductive layer-tunable graphene by simply controlling the exfoliating temperature
Ping Wang1, Bin Guo1, Huaxin Ma1
1State Key Laboratory of Metastable Materials Science and Technology, Yanshan University, Qinhuangdao 066004, People's Republic of China.
None:
The development of effective strategies for the massive production of layer-number tunable graphene is of great importance to satisfy the requirements in versatile applications such as energy storage, thermal management, photocatalysis. However, how to prepare the layer-tunable graphene by a simple and efficient way is still a great challenge. Herein, an attempt has been made to exfoliate graphite into layer-tunable graphene by simply soaking the graphite in a binary-component solution composed of H2SO4 and (NH4)2S2O8. In this one-step method, we demonstrate that the layer-number for the as-prepared graphene can be significantly reduced by increasing the exfoliating temperature. An average thickness of ∼20, ∼10, and ∼3 atomic layers can be obtained for the graphene samples exfoliated at the temperature of 30 °C, 60 °C, and 90 °C, respectively. Meanwhile, higher exfoliating temperature not only facilitates the higher efficiency in the exfoliation of graphite, but also achieves a superior conductivity for the prepared graphene. We have demonstrated for the first time that controlling in a sole factor of temperature can effectively tune the layer-number of graphene by a one-step chemical exfoliation method, which will find its great potential in the practical application where the designated property of graphene is required.
More Related Videos
08:54Synthesis and Exfoliation of Discotic Zirconium Phosphates to Obtain Colloidal Liquid Crystals
Published on: May 25, 2016
10:41Preparation of Liquid-exfoliated Transition Metal Dichalcogenide Nanosheets with Controlled Size and Thickness: A State of the Art Protocol
Published on: December 20, 2016
Related Concept Videos
Chemical Agents for Microbial Control
Physical Methods for Controlling Microbial Growth: Temperature
Physical and Chemical Properties of Matter
Conduct Disorder
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...