[Study on calculation method of internal and external fluid capacity of human cells based on bioimpedance
Li Ke1, Jiawei Xu2, Yunan Zhao1
1Institute of Biomedical and Electromagnetic Engineering, Shenyang University of Technology, Shenyang 110870, P.R.China.
Abstract:
Bioelectrical impedance measurement technology is a non-invasive detection technology for extracting human physiological and pathological information. The analysis method of the relationship between bioimpedance and human physiological parameters is an important part of this technology. In order to calculate the internal and external liquid volume of human cells more accurately, based on the Moissl equation for calculating the internal and external fluid volume of human cells, a segmented human bioimpedance spectrum measurement model and an improved calculation method of intracellular and external fluid capacity were proposed. The measurement and calculation experiments of the intracellular and extracellular fluid volume before and after the human body's water intake were designed and compared with the Moissl calculation method. The results show that the improved calculation method can calculate the intracellular and extracellular fluid volumes more effectively, and the relative error is less than 5%, which may provide new ideas or more accurate methods for the analysis of human body components, facilitating the diagnosis and treatment of diseases.
More Related Videos
06:48Fluid-cell Raman Spectroscopy for operando Studies of Reaction and Transport Phenomena during Silicate Glass Corrosion
Published on: May 9, 2025
09:58A Choroid Plexus Epithelial Cell-based Model of the Human Blood-Cerebrospinal Fluid Barrier to Study Bacterial Infection from the Basolateral Side
Published on: May 6, 2016
Related Concept Videos
External and Internal Respiration
Internal and External Forces
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Lung Capacity
Internal Receptors
