Lead Removal Without Extraction Tools: A Single-Center Experience
Neiberg de Alcantara Lima1,2, Gisele Schinaider Cunha3, Natalia Soares de Menezes2
1Western Michigan University Michigan United States Western Michigan University, Michigan, United States.
Simple manual traction is an effective method for cardiac device lead extraction, achieving high success rates without complications. This technique is a viable first-line approach, especially in resource-limited settings, before considering more complex tools.
Area of Science:
- Cardiology
- Medical Devices
- Surgical Procedures
Background:
- Cardiac device implantation is increasing, leading to a greater need for lead extraction due to infections, lead failure, and device recalls.
- Advanced technological tools like powered laser sheaths exist for lead extraction but present significant economic challenges.
Purpose of the Study:
- To evaluate the efficacy of simple manual traction for transvenous lead extraction.
- To question the necessity of expensive, technologically advanced devices in lead extraction procedures.
Main Methods:
- Retrospective observational study of 35 patients undergoing transvenous lead extraction.
- Data collected via records review, analyzing patient demographics, device information, dwelling time, extraction indications, and outcomes.
- Simple manual traction was the primary extraction technique assessed.
Main Results:
- The median dwelling time for cardiac devices was 46.22 months.
- Common indications for lead extraction included infection, lead fracture, and device malfunction.
- Simple manual traction was used in 88.9% of cases, achieving a 90% success rate with complete removal and no immediate complications.
Conclusions:
- Simple manual traction is an effective and successful method for transvenous lead extraction.
- This technique is a cost-effective first-line approach, particularly in economically challenged regions.
- Auxiliary tools should be reserved for cases where simple manual traction fails or is contraindicated.
Related Concept Videos
Phase-lead and Phase-lag Controllers
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Extraction: Effects of pH
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Extraction: Advanced Methods