Introduction:
Indications for cardiac devices have been increasing as well as the need for lead extractions as a result of infections, failed leads and device recalls. Powered laser sheaths, with a global trend towards the in-creasingly technological tools, meant to improve the procedure's outcome but have economic implications.
Objective:
The aim of this study is to demonstrate the experience of a Bra-zilian center that uses simple manual traction in most lead removals per-formed annually, questioning the real need for expensive and technically challenging new devices.
Methods:
This retrospective observational study included 35 patients who had a transvenous lead extraction in the period of a year between January 1998 and October 2014 at Hospital de Messejana Dr. Carlos Alberto Studart Gomes, in Fortaleza, CE, Brazil. Data were collected through a records review. They were evaluated based on age, type of device, dwelling time, indication for removal, technique used and immediate outcomes.
Results:
The median dwelling time of the devices was 46.22 months. Infec-tion, lead fracture and device malfunction were the most common indica-tions. Simple traction was the method of choice, used in 88.9% of the pro-cedures. Manual traction presented high success rates, resulting in com-plete removal without complications in 90% of the cases.
Conclusion:
This article suggests that lead extraction by simple manual traction can still be performed effectively in countries with economic diffi-culties as a first attempt, leaving auxiliary tools for a second attempt in case of failure or contraindications to the simple manual traction technique.
Related Concept Videos
Phase-lead and Phase-lag Controllers
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Extraction: Effects of pH
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Extraction: Advanced Methods