Related Experiment Video
Updated: Jan 20, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Ventilatory Efficacy After Transcatheter Aortic Valve Replacement Predicts Mortality and Heart Failure Events in
Makoto Murata1, Hitoshi Adachi1, Taisuke Nakade1
1Department of Cardiology, Gunma Prefectural Cardiovascular Center.
Background:
We aimed to clarify the predictors of death or heart failure (HF) in elderly patients who undergo transcatheter aortic valve replacement (TAVR).
Methods And Results:
We prospectively enrolled 83 patients (age, 83±5 years) who underwent transthoracic echocardiography (TTE) and cardiopulmonary exercise testing (CPET) with impedance cardiography post-TAVR. We investigated the association of TTE and CPET parameters with death and the combined outcome of death and HF hospitalization. Over a follow-up of 19±9 months, peak oxygen uptake (V̇O2) was not associated with death or the combined outcome. The minimum ratio of minute ventilation (V̇E) to carbon dioxide production (V̇CO2) and the V̇E vs. V̇CO2slope were higher in patients with the combined outcome. After adjusting for age, sex, Society of Thoracic Surgeons score and peak V̇O2, ventilatory efficacy parameters remained independent predictors of the combined outcome (minimum V̇E/V̇O2: hazard ratio, 1.108; 95% confidence interval, 1.010-1.215; P=0.031; V̇E vs. V̇CO2slope: hazard ratio, 1.035; 95% confidence interval, 1.001-1.071; P=0.044), and had a greater area under the receiver-operating characteristic curve. The V̇E vs. V̇CO2slope ≥34.6 was associated with higher rates of the combined outcome, as well as lower cardiac output at peak work rate during CPET.
Conclusions:
In elderly patients, lower ventilatory efficacy post-TAVR is a predictor of death and HF hospitalization, reflecting lower cardiac output at peak exercise.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
08:50Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
07:46Automatic Surgery in Transcatheter Aortic Valve Replacement Using Augmented Reality