Related Experiment Video
Updated: Jan 20, 2026

Development of an Electrochemical DNA Biosensor to Detect a Foodborne Pathogen
Published on: June 3, 2018
Dependent signal quenching and enhancing triggered by bipedal DNA walker for ultrasensitive photoelectrochemical
Minghui Zhu1, Xia Zhong1, Hanmei Deng1
1Education Ministry Key Laboratory on Luminescence and Real-Time Analysis, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, People's Republic of China.
Abstract:
Herein, by utilizing bipedal DNA walker as booster to adjust the distance of quencher ferrocene (Fc) and sensitizer methylene blue (MB) to photoactive material perylene-3,4,9,10-tetracarboxylic acid (PTCA), a novel "on-off-super on" photoelectrochemical (PEC) biosensor was proposed for ultrasensitive detection of thrombin (TB). Firstly, the PTCA matrix on electrode could provide a high initial PEC signal assisted by depAu. Upon the Fc labeled on hairpin DNA 1 (H1-Fc) proximate to PTCA, the PEC signal could obviously decrease to reduce the background signal. Interestingly, the target TB-related bipedal DNA walker implemented the opening of H1-Fc for the departure of Fc toward PTCA, which achieved the recovery of PEC signal and exposed the prelocked toehold domain for the hybridization with hairpin DNA 2 labeled with MB (H2-MB), thereby making the MB approach to PTCA for achieving the "super on" signal. As a result, this proposed strategy showed a wide linear range from 0.5 fM to 100 nM with a low detection limit down to 0.17 fM for TB detection, providing an efficient and available avenue for sensitive detection of biomolecules in bioanalysis and disease diagnosis.
Related Concept Videos
Quenching and Boiling
Controlled heating followed by rapid cooling is an important element of many materials processing applications. This heat-treating procedure can increase material hardness, which is important for cutting tools or surfaces in high wear environments. The rapid cooling stage is called quenching, and is often performed by immersing...
17:16Development of an Electrochemical DNA Biosensor to Detect a Foodborne Pathogen
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
08:58Cerebral Blood Oxygenation Measurement Based on Oxygen-dependent Quenching of Phosphorescence
08:22Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
13:15Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
