High-speed OCT-based ocular biometer combined with an air-puff system for determination of induced retraction-free

Alfonso Jiménez-Villar1, Ewa Mączyńska1, Artur Cichański2

  • 1Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, ul. Grudziądzka 5, 87-100 Toruń, Poland.

Related Concept Videos

Ex Vivo OCT-Based Multimodal Imaging of Human Donor Eyes for Research into Age-Related Macular Degeneration10:14

Ex Vivo OCT-Based Multimodal Imaging of Human Donor Eyes for Research into Age-Related Macular Degeneration

Laboratory assays can leverage prognostic value from the longitudinal optical coherence tomography (OCT)-based multimodal imaging of age-related macular degeneration (AMD). Human donor eyes with and without AMD are imaged using OCT, color, near-infrared reflectance scanning laser ophthalmoscopy, and autofluorescence at two excitation wavelengths prior to tissue...
4.2K
Experimental Glaucoma Induced by Ocular Injection of Magnetic Microspheres06:35

Experimental Glaucoma Induced by Ocular Injection of Magnetic Microspheres

We present a method for inducing elevated intraocular pressure (IOP), by injecting magnetic microspheres into the rat eye, to model glaucoma. This leads to strong pressure rises, and extensive neuronal death. This protocol is easy to perform, does not require repeat injections, and produces stable long-lasting IOP...
17.8K
Sample Preparation for Mass-spectrometry-based Proteomics Analysis of Ocular Microvessels11:32

Sample Preparation for Mass-spectrometry-based Proteomics Analysis of Ocular Microvessels

Proteome characterization of ocular microvascular beds is pivotal for in-depth understanding of many ocular pathologies in humans. This study demonstrates an effective, rapid, and robust method for protein extraction and sample preparation from small blood vessels employing the porcine short posterior ciliary arteries as model vessels for mass-spectrometry-based proteomics...
11.9K
Whole-cell Currents Induced by Puff Application of GABA in Brain Slices07:32

Whole-cell Currents Induced by Puff Application of GABA in Brain Slices

We describe the puff technique, by which pharmacological reagents can be administered during whole-cell patch-clamp recording, and highlight various aspects of the features that are crucial for its...
9.9K
Pitot-static Tube: A Device to Measure Air Flow Speed07:28

Pitot-static Tube: A Device to Measure Air Flow Speed

Source: David Guo, College of Engineering, Technology, and Aeronautics (CETA), Southern New Hampshire University (SNHU), Manchester, New Hampshire
A Pitot-static tube is widely used for measuring unknown speeds in air flow, for example, it is used to measure airplane airspeed. By Bernoulli's principle, airspeed is directly related to variations in pressure. Therefore, the Pitot-static tube senses the stagnation pressure and static pressure. It is connected to a manometer or pressure transducer...
51.0K
A Reversible Silicon Oil-Induced Ocular Hypertension Model in Mice09:03

A Reversible Silicon Oil-Induced Ocular Hypertension Model in Mice

Here, we present a protocol to induce ocular hypertension and glaucomatous neurodegeneration in mouse eyes by intracameral injection of silicone oil and the procedure for silicone oil removal from the anterior chamber to return elevated intraocular pressure to...
10.7K