Design of an ultra-thin steerable probe for percutaneous interventions and preliminary evaluation in a gelatine

Marta Scali1, Paulien A H Veldhoven1, Paul W J Henselmans1

  • 1Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Delft, The Netherlands.

Plos One
|September 5, 2019
PubMed

Related Concept Videos

Viscoelastic Characterization of Soft Tissue-Mimicking Gelatin Phantoms using Indentation and Magnetic Resonance Elastography07:57

Viscoelastic Characterization of Soft Tissue-Mimicking Gelatin Phantoms using Indentation and Magnetic Resonance Elastography

This article presents a demonstration and summary of protocols of making gelatin phantoms that mimic soft tissues, and the corresponding viscoelastic characterization using indentation and magnetic resonance...
2.6K
Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training09:57

Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training

Here we present development of a mock circulation setup for multimodal therapy evaluation, pre-interventional planning, and physician-training on cardiovascular anatomies. With the application of patient-specific tomographic scans, this setup is ideal for therapeutic approaches, training, and education in individualized...
4.6K
A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair08:31

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair

This protocol presents in detail how to perform real-time echocardiographic guidance during transcatheter mitral valve repair. The fundamental views and the necessary measurements are described for each stage of the procedure.
4.3K
A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump09:04

A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump

A simulation model specifically supporting the preliminary design of an electro-variable displacement pump (EVDP) is developed and partially verified by experiments. The control performance, life, reliability, etc., can all be evaluated using the proposed model, which covers the main performance requirements under the EVDP preliminary design...
3.6K
Validation of a Psychosocial Intervention on Body Image in Older People: An Experimental Design07:40

Validation of a Psychosocial Intervention on Body Image in Older People: An Experimental Design

This experimental intervention examines the body satisfaction of older people. The aim is to compare a specific intervention with another general program and determine which is more effective for improving body satisfaction in people over fifty years...
3.8K
A Stable Phantom Material for Optical and Acoustic Imaging04:54

A Stable Phantom Material for Optical and Acoustic Imaging

This protocol describes the fabrication of a stable, biologically relevant phantom material for optical and acoustic biomedical imaging applications, featuring independently tunable acoustic and optical properties.
3.7K