Related Experiment Video
Updated: Jan 20, 2026

Substernal Thyroid Biopsy Using Endobronchial Ultrasound-guided Transbronchial Needle Aspiration
Published on: November 10, 2014
A novel technique for retrieval of a broken biopsy needle
Walker Asprey1, Grace Knuttinen2, Jeremiah R Long2
1Mayo Clinic Alix School of Medicine, 13400 E. Shea Blvd., Scottsdale, AZ, 85259, USA.
Abstract:
A broken needle is a rare complication of bone biopsy. We describe an easily applied technique of retrieval of a retained biopsy needle fragment using a cannulated drill typically used for internal fixation of femoral neck fractures. This approach allows for removal under moderate conscious sedation and can be performed by a radiologist using fluoroscopic or CT-fluoroscopic guidance in the radiology suite.
Related Concept Videos
10:19Substernal Thyroid Biopsy Using Endobronchial Ultrasound-guided Transbronchial Needle Aspiration
14:53Bovine Mammary Gland Biopsy Techniques
09:26Preparation and Using Phantom Lesions to Practice Fine Needle Aspiration Biopsies
11:27Preparation and Respirometric Assessment of Mitochondria Isolated from Skeletal Muscle Tissue Obtained by Percutaneous Needle Biopsy
09:01A Technique for Subcutaneous Abdominal Adipose Tissue Biopsy via a Non-diathermy Method
07:20Human Skeletal Muscle Biopsy Procedures Using the Modified Bergström Technique