Objective:
To evaluate the association of the duration of the detailed fetal anatomic ultrasound examination with maternal body mass.
Methods:
This was a retrospective chart review of patients presenting to our clinic for detailed fetal anatomic examinations between January 1, 2010, and June 30, 2017. After excluding multifetal pregnancies and other examinations expected to have a longer duration, a total of 6,522 examinations were performed between 18 0/7 and 22 0/7 weeks of gestation. Results were analyzed using analysis of variance and Student's t-test.
Results:
Mean (SD) body mass index (BMI) was 29.3 (±7.7), and mean examination time was 51.5 (±10.4) minutes. We found that mean examination time was 48.8 (±9.6) minutes for patients with normal BMIs, 50.6 (±10.0) minutes for overweight patients, 52.2 (±10.4) minutes for patients with class I obesity, 54.6 (±10.3) minutes for patients with class II obesity, and 57.7 (±10.3) minutes for patients with class III obesity (P<.001). The duration of the detailed fetal anatomic ultrasound examination increased continuously with BMI (r=0.285, P<.001).
Conclusion:
We found that the duration of detailed fetal anatomic examinations increased with BMI. Examinations for gravid patients with class III obesity lasted 8.9 minutes longer than those for gravid patients with normal BMIs; examinations for gravid patients with BMIs of 50 or higher lasted 13.5 minutes longer. This information may be useful for fetal ultrasound examination scheduling.
Related Concept Videos
14:19Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
07:34Fetal Mouse Cardiovascular Imaging Using a High-frequency Ultrasound (30/45MHZ) System
06:43High Frequency Ultrasound for the Analysis of Fetal and Placental Development In Vivo
10:02Whole-body PET/MRI of Pediatric Patients: The Details That Matter
The Implicit Association Test
One of the core constructs in social psychology is the notion of an attitude toward an object or person. Traditionally, psychologists measured attitudes by simply asking people to self-report their beliefs, opinions, or feelings. This approach has limitations, however, when measuring socially sensitive attitudes, like racial prejudice, because people are often motivated to self-report unprejudiced, egalitarian beliefs (despite...
Reduced Mass Coordinates: Isolated Two-body Problem