Self-calibrated and SNR-enhanced particle holography

Summary

This study introduces a self-calibrated method for in-line particle holography, reducing speckle noise by estimating illumination angles directly from holograms, eliminating the need for manual system calibration.

Related Concept Videos

Enhancing Density Maps by Removing the Majority of Particles in Single Particle Cryogenic Electron Microscopy Final Stacks06:41

Enhancing Density Maps by Removing the Majority of Particles in Single Particle Cryogenic Electron Microscopy Final Stacks

An advanced particle selection method for cryo-EM, namely CryoSieve, improves density map resolution by removing a majority of particles in final stacks, as demonstrated through its application on a real-world...
2.6K
Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.3K
Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
687
Calibration Curves07:43

Calibration Curves

Source: Laboratory of Dr. B. Jill Venton - University of Virginia
Calibration curves are used to understand the instrumental response to an analyte and predict the concentration in an unknown sample. Generally, a set of standard samples are made at various concentrations with a range than includes the unknown of interest and the instrumental response at each concentration is recorded. For more accuracy and to understand the error, the response at each concentration can be repeated so an error...
818.7K
MRM Microcoil Performance Calibration and Usage Demonstrated on Medicago truncatula Roots at 22 T10:22

MRM Microcoil Performance Calibration and Usage Demonstrated on Medicago truncatula Roots at 22 T

A protocol to study biological tissue at high spatial resolution using ultra-high field magnetic resonance microscopy (MRM) using microcoils is presented. Step-by-step instructions are provided for characterizing the microcoils. Finally, optimization of imaging is demonstrated on plant...
5.9K
Plotting and Calibrating the Root Locus01:19

Plotting and Calibrating the Root Locus

Root loci often diverge as system poles shift from the real axis to the complex plane. Key points in this transition are the breakaway and break-in points, indicating where the root locus leaves and reenters the real axis. The branches of the root locus form an angle of 180/n degrees with the real axis, where n is the number of branches at a breakaway or break-in point.
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
438