Safety and Effectiveness of the Pipeline Flex Embolization Device With Shield Technology for the Treatment of
Felipe Padovani Trivelato1, Eduardo Wajnberg2, Marco Túlio Salles Rezende1
1Division of Interventional Neuroradiology, Felício Rocho Hospital, Belo Horizonte, Brazil.
Background:
The safety and efficacy of the first generation of the Pipeline Embolization Device (PED; Medtronic Inc) have been proven in large case series. Ischemic events are one of the most common complications following treatment of aneurysms with flow diverters. The new PED Flex with Shield technology (PED Shield; Medtronic Inc) was introduced to minimize the rate of complications.
Objective:
To evaluate the outcomes of patients harboring aneurysms treated with the PED Shield.
Methods:
This was an observational, prospective, single-arm multicenter study of patients treated with the PED Shield. The primary safety endpoint was the absence of major neurological complications and death. The secondary effectiveness endpoint was angiographic occlusion at 6 and 12 mo. Technical complications were also reported.
Results:
Between November 2017 and December 2018, 151 patients from 7 centers with 182 aneurysms were enrolled. The mean aneurysm size was 7.0 mm; 27 (14.8%) aneurysms were large, and 7 (3.8%) were giant. In 141 of 151 patients (93.4%), the primary endpoint was reached. The overall rate of periprocedural complications was 7.3%. Of the aneurysms, 79.7% met the study's secondary endpoint of complete occlusion at 6 mo and 85.3% at 12 mo.
Conclusion:
The PED Shield is a safe and effective treatment for intracranial aneurysms. The results regarding total occlusion and ischemic complications did not differ from those obtained in case series using previous versions of the PED. Long-term follow-up and comparative studies are required to provide stronger conclusions regarding the reduced thrombogenicity of this device.
More Related Videos
11:07Biodegradable Magnesium Stent Treatment of Saccular Aneurysms in a Rat Model - Introduction of the Surgical Technique
Published on: October 1, 2017
03:06Combination of High Ligation and Intraoperative Embolization using Polidocanol for Treatment of Varicoceles
Published on: December 22, 2023
Related Concept Videos
07:21Microsurgical Creation of Giant Bifurcation Aneurysms in Rabbits for the Evaluation of Endovascular Devices
11:07Biodegradable Magnesium Stent Treatment of Saccular Aneurysms in a Rat Model - Introduction of the Surgical Technique
03:06Combination of High Ligation and Intraoperative Embolization Using Polidocanol for Treatment of Varicoceles
04:34Meta-Analysis of the Effectiveness and Safety of Shugan Jieyu Capsules for the Treatment of Insomnia
07:34Microsurgical Venous Pouch Arterial-Bifurcation Aneurysms in the Rabbit Model: Technical Aspects
08:11A Simple Guide Screw Method for Intracranial Xenograft Studies in Mice