Feasibility of novel in vivo EPID dosimetry system for linear accelerator quality control tests

Fatih Biltekin1, Yagiz Yedekci2, Gokhan Ozyigit2

  • 1Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, 06100, Ankara, Turkey. fatih.biltekin@hacettepe.edu.tr.

Related Concept Videos

Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments06:08

Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments

Clinical linear accelerators can be used to determine biologic effects of a wide range of dose rates on cancer cells. We discuss how to set up a linear accelerator for cell-based assays and assays for cancer stem-like cells grown as tumorspheres in suspension and cell lines grown as adherent...
7.9K
Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator07:31

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator

A growing number of radiation therapy devices offer the advantage of delivering the dose through very small beams to the tumor, allowing for increased conformity and higher doses per fraction. Many different detectors can be used for the dosimetry of these small fields. In the present study, the effect of ion recombination is investigated for a liquid ionization chamber using a stereotactic radiation therapy...
12.2K
Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities06:51

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities

This document describes a new dosimetry protocol for cell irradiations using low energy X-ray equipment. Measurements are performed in conditions simulating real cell irradiation conditions as much as...
5.5K
Quality Control01:05

Quality Control

Quality control is one of the three cyclical quality assurance activities that help keep a system under statistical control. Typical quality control activities include creating quality control charts, conducting proficiency testing, and documenting and archiving results.
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
1.2K
Linear Momentum in Control Volume01:13

Linear Momentum in Control Volume

Newton's second law is applied to obtain the linear momentum in a control volume in a fluid system. According to this law, the rate of change of linear momentum is equal to the sum of external forces acting on the system. When a control volume matches the fluid system at a specific moment, the forces acting on both are identical. Reynolds transport theorem helps explain this by breaking down the system's linear momentum into two components: the rate of change of linear momentum within...
1.3K
Testing Water Quality01:14

Testing Water Quality

When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
372