Experience in multicatheter interstitial high-dose-rate breast brachytherapy: dose-volume histogram analysis of the
Alena Demianovich1, Dmitriy Sanin1, Valeriya Martynova1
1A. Tsyb Medical Radiological Research Centre - branch of the National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, Obninsk, Russia.
Purpose:
To report characteristics of our treatment scheme of high-dose-rate (HDR) brachytherapy of breast cancer and to show the first outcomes of dosimetric planning analysis based on dose-volume histogram (DVH).
Material And Methods:
Since August 2017, 25 patients diagnosed with T1N0M0 breast cancer have received a treatment in our center. There was lumpectomy and following breast HDR brachytherapy (10 fractions of 3.4 Gy) administered to each patient. A planning target volume (PTV) and organs at risk (OARs) were recorded with DVH analysis.
Results:
The study describes the full procedure of breast HDR brachytherapy with the lumpectomy. Twenty-five patients were treated, including 9 with cancer of the left breast and 16 of the right breast. The median age was 65 years. The first analysis of DVH data shows that the main OARs were ribs and skin. Mean value of Dmax (ribs) for all patients was 19.90 Gy (55.88% of prescribed dose) and for the skin 30.88 Gy (90.74% of prescribed dose). During the treatment, there was only one case of toxic effects, which was pigmentation on the skin due to excess of dose limit of 1.4 Gy. Therefore, the limit exceeding of 1 Gy does not give any significant toxic effects.
Conclusions:
This study is the first stage of the dosimetric evaluation of a new method. The analysis allows treating complex localizations of the breast cancer, for example, in a close position to the skin or ribs. In order to minimize the toxic effects, it is necessary to consider patient selection, catheter administration, and dose optimization.
Related Concept Videos
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
06:24Minimal Erythema Dose (MED) Testing