Inferior extended fixation utilizing porous titanium augments improves primary anti-rotational stability of the

Hao Tang1, Baochun Zhou2, Yong Huang1

  • 1Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China.

Abstract

Related Concept Videos

Plasma Polishing as a New Polishing Option to Reduce the Surface Roughness of Porous Titanium Alloy for 3D Printing06:12

Plasma Polishing as a New Polishing Option to Reduce the Surface Roughness of Porous Titanium Alloy for 3D Printing

Plasma polishing is a promising surface processing technology, especially suitable for 3D printing of porous titanium alloy workpieces. It can remove semi-molten powders and ablative oxide layers, thereby effectively reducing surface roughness and improving surface...
2.3K
Stabilizing a Femur Osteotomy with a Plate Fixation in Ambystoma mexicanum05:45

Stabilizing a Femur Osteotomy with a Plate Fixation in Ambystoma mexicanum

A protocol for femoral osteotomy surgery with the use of internal plate fixation in mature axolotls is presented. The procedure can be used to perform comparative studies on limb regeneration and fracture healing in aquatic...
919
Improved Suspension Fixation Using Rat Jacket in Rat Acupuncture Experiments05:42

Improved Suspension Fixation Using Rat Jacket in Rat Acupuncture Experiments

Here, we present an improved suspension fixation method using a rat jacket to effectively immobilize rats during acupuncture experiments. Furthermore, the structure and application of this fixation apparatus, as well as instructions and evaluation for its utilization in electroacupuncture therapy, is elucidated.
2.0K
Augmenting Large Language Models via Vector Embeddings to Improve Domain-Specific Responsiveness03:14

Augmenting Large Language Models via Vector Embeddings to Improve Domain-Specific Responsiveness

In this protocol, foundation large language model response quality is improved via augmentation with peer-reviewed, domain-specific scientific articles through a vector embedding mechanism. Additionally, code is provided to aid in performance comparison across large language...
1.0K
Extended 78% Hepatectomy in a Mouse Surgical Model05:25

Extended 78% Hepatectomy in a Mouse Surgical Model

The mouse model of partial 2/3 (66%) hepatectomy is well described in the literature, but more extended hepatectomies mimicking small-for-size syndrome after liver transplantation have seldom been used. We describe an extended 78% hepatectomy procedure in a mouse model that results in approximately 50% postoperative lethality in healthy mice.
3.4K
The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve09:51

The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve

The anterior-based muscle-sparing approach for total hip arthroplasty (THA) is associated with a learning curve. However, the improved clinical outcome in the early post-operative phase makes the consideration to transition worthwhile.
3.5K