Do Oblique Cyclic Loads Influence the Tensile Strength of Different Morse Taper Connection Abutments?
Purpose:
The purpose of this in vitro study was to evaluate the behavior of abutments attached to Morse taper connection implants, with and without internal index, against oblique cyclic loads.
Materials And Methods:
Twenty test pieces composed of abutments connected to Morse taper implants solely by friction action were subdivided into two groups (n = 10): group NI (no index) and group I (index). The test units were submitted to tensile tests, before and after cycling loads. Paired t tests were used for intragroup data at different times, and independent t tests were used for the comparisons between the groups.
Results:
There was a statistically significant difference in both the groups when the precycling and postcycling tensile values were compared. In the comparison between the no index and index groups, there was no statistically significant difference in precycling and postcycling tests.
Conclusion:
Within the limitations of this in vitro study, it can be concluded that the cyclic loads increased the tensile strength of abutments on Morse taper implants regardless of the index presence. On the other hand, the presence of an index did not significantly alter the values of tensile tests, before and after cyclic loads.
Related Concept Videos
Tensile Strength of Resorbable Biomaterials
For over 4000 years, sutures have been used as a medical intervention. The earliest records indicate linen was the biomaterial of choice. Catgut, which is still in use today, was reportedly used to treat gladiators around 150 AD. Today, there are numerous materials being used for sutures. Sutures are classified by their composition (natural or...
10:32Using Q Suture to Enhance Resistance to Gap Formation and Tensile Strength of Repaired Flexor Tendons
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Relation Between Tensile Strength and Compressive Strength of Concrete
Cyclic Voltammetry (CV)
A Cyclic Voltammetry (CV) experiment involves the scan of a range of potential voltages while measuring current. In the CV experiment, the potential of an immersed, stationary electrode is scanned from a predetermined starting potential to a final value (called the switching potential) and then the reverse scan is obtained. This gives a 'cyclic' sweep of potentials and the current vs. potential curve derived from...
05:04A Non-Invasive Method for Generating the Cyclic Loading-Induced Intra-Articular Cartilage Lesion Model of the Rat Knee