Polymer-based flexible NOx sensors with ppb-level detection at room temperature using breath-figure molding
Seong Hoon Yu1, Henok Getachew Girma, Kyu Min Sim
1Department of Energy Science and Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu 42988, Republic of Korea. dchung@dgist.ac.kr.
Abstract:
A strategically designed polymer semiconductor thin film morphology with both high responsivity to the specific gas analyte and high signal transport efficiency is reported to realize high-performance flexible NOx gas sensors. Breath-figure (BF) molding of polymer semiconductors enables a finely defined degree of nano-porosity in polymer films with high reproducibility while maintaining high charge carrier mobility characteristics of organic field effect transistors (OFETs). The optimized BF-OFET with a donor-acceptor copolymer exhibits a maximum responsivity of over 104%, sensitivity of 774% ppm-1, and limit of detection (LOD) of 110 ppb against NO at room temperature. When tested across at NO concentrations of 0.2-10 ppm, the BF-OFET gas sensor exhibits a response time of 100-300 s, which is suitable for safety purposes in practical applications. Furthermore, BF-OFETs show a high reproducibility as confirmed by statistical analysis on 64 independently fabricated devices. The selectivity of NOx analytes is tested by comparing the sensing ability of BF-OFETs with those of other reducing gases and volatile organic compounds; the BF-OFET gas sensor platform monitors specific gas analytes based on their polarity and magnitude of sensitivity. Finally, flexible BF-OFETs conjugated with plastic substrates are demonstrated and they exhibit a sensitivity of 500% ppm-1 and a LOD of 215 ppb, with a responsivity degradation of only 14.2% after 10 000 bending cycles at 1% strain.