Pressure Signal Enhancement of Slowly Increasing Leaks Using Digital Compensator Based on Acoustic Sensor
Fang Wang1, Weiguo Lin2, Zheng Liu3
1College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China. 2016400136@mail.buct.edu.cn.
Abstract:
Pipeline leak detection technologies are critical for the safety protection of pipeline transportation. However, they are insensitive to slowly increasing leaks. Therefore, this study proposes an enhancement method for slowly increasing leak signals. By analyzing the characteristics of pressure signals of slowly increasing leaks, a digital compensator is developed to overcome the disadvantages of pressure signals and enhance the pressure signals. According to the frequency response analysis of the digital compensator, the enhancement principle is the parameter adjustment of the digital compensator. Therefore, this paper further proposes an adaptive adjustment method of the parameter to enhance different degrees of leak signals online in real-time, and the proposed method is evaluated using two field pipelines. The experimental results demonstrate that this method is suitable not only for enhancing slowly increasing leaks but also for enhancing abrupt leaks.
Related Concept Videos
Sound as Pressure Waves
The pressure fluctuation depends on the difference in displacements between the successive points in the...
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...