Related Experiment Video
Updated: Aug 6, 2026

Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Lower Radiation Dosing in Cardiac Computed Tomographic Angiography: the CONVERGE Registry
Paul Madaj1, Dong Li1, Rine Nakanishi1
1Los Angeles Biomedical Research Institute, United States.
Abstract:
Intro: Coronary artery disease is the leading cause for morbidity and mortality. Tools have been developed to accurately diagnose and evaluate coronary artery disease. Coronary computed tomographic angiography (CCTA) scans provide detailed imaging along with analysis to in order to deliver precise analysis and prognostic information. We sought to evaluate the radiation doses of the 256 detector CT scanner to a 64 slice scanner across a similar profile of patients. Methods: Consecutive patients were screened, enrolled, and consented for the Converge Registry study, in accordance with the Institutional Review Board (IRB) approved protocol. 110 patients underwent CCTA using the GE Revolution 256 detector CT scanner. We matched patients by age, gender and body mass index (BMI) who underwent 64 slice CT scanning. Results: We compared 110 patients in each group. We found that mean dose length product (DLP, presented also in the tables below in millisieverts (mSv)) was significantly lower in the Revolution 256 detector group compared to the 64 slice control group (p<0.05). The radiation dose was reduced 32% with use of Revolution 256 detector scanner for BMI between 18.5 and 24.9 (DLP = 111.2 vs 76.1; 1.56 vs 1.07 mSv; p<0.05). For each BMI subgroup, there was a significant decrease in dose. Regression analysis found that with the increase in BMI both scanners experienced a significant increase in DLP. Conclusion: We are able to demonstrate that the 256 slice CT scanner is able to provide CCTA scans at significantly lower radiation doses compared to the 64 row scanner at different BMI groups, with all other variables accounted for. Lower radiation exposures along with lower contrast requirements can provide quality imaging with high diagnostic accuracy and less risk to the patient.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography