Related Experiment Video
Updated: Jan 5, 2026

Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Screen-Printed Voltammetric Biosensors for the Determination of Copper in Wine
Liliana Norocel1, Gheorghe Gutt2
1Department of Health and Human Development, Stefan cel Mare University of Suceava, 13, University Street, 720229 Suceava, Romania. liliana.norocel@fia.usv.ro.
Abstract:
Certain heavy metals present in wine, including copper, can form insoluble salts and can induce additional casse, so their determination is important for its quality and stability. In this context, a new biosensor for quantification of copper ions with BSA protein (bovine serum albumin) and using SPE electrodes (screen-printed electrodes) is proposed. The objective of this research was to develop a miniaturized, portable, and low-cost alternative to classical methods. A potentiostat, which displays the response in the form of a cyclic voltammogram, was used in order to carry out this method. Values measured for the performance characteristics of the new biosensor revealed a good sensitivity (21.01 μA mM-1cm-2), reproducibility (93.8%), and limit of detection (0.173 ppm), suggesting that it has a high degree of application in the analysis proposed by our research. The results obtained for wine samples were compared with the reference method, atomic absorption spectrometer (AAS), and it was indicated that the developed biosensor is efficient and can be used successfully in the analysis of copper in wine. For the 20 samples of red wine analyzed with AAS, the concentration range of copper was between 0.011 and 0.695 mg/L and with the developed biosensor it was between 0.037 and 0.658 mg/L. Similar results were obtained for the 20 samples of white wine, 0.121-0.765 mg/L (AAS) and 0.192-0.789 mg/L (developed biosensor), respectively.
More Related Videos
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Amperometry: Overview
Voltammetric Techniques: Pulse Voltammetry