Related Experiment Video
Updated: Jan 4, 2026

Electrochemiluminescence Assays for Human Islet Autoantibodies
Published on: March 23, 2018
[Anti-estreptavidin antibodies. Diagnostic confusion by biochemical interference]
Marina T Bergoglio1, Gabriela A Sosa1, María E Inchauspe2
1Servicio de Endocrinología, Sanatorio Allende, Córdoba, Argentina.
Abstract:
We present the case of a patient who, during studies for fertility and subsequent pregnancy, showed an altered thyroid profile with elevated levels of free T4 and normal TSH. After ruling out a thyrotropic adenoma and in the absence of clinical symptoms of hyperthyroidism, the possibility of analytical interference in the immunoassays used to measure hormones was investigated. Interferences caused by heterophile antibodies, macro TSH, anti-thyroid antibodies, biotin, and to a lesser extent anti-streptavidin and anti-ruthenium antibodies have been described. The analysis of the patient was carried out in a self-analyzer whose platform uses the streptavidin-biotin system that is very susceptible to several interferents. A proposed algorithm includes a series of simple tests to perform and interpret that allow detecting or ruling out the presence of interferents. Accordingly, a comparison was made with a different analytical platform (which does not use the streptavidin-biotin system), serial dilutions, precipitation with polyethylene glycol 6000 and treatment with microparticles coated with streptavidin. Results obtained confirmed the presence of anti-streptavidin antibodies in the patient's serum. In the case of disagreements between clinical manifestations and laboratory results, the possibility of methodological interferences should be investigated in order to avoid the potential iatrogenic risk involved in an erroneous biochemical interpretation.
More Related Videos
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...