Fast Automatic Detection of Large Vessel Occlusions on CT Angiography
Shalini A Amukotuwa1,2,3, Matus Straka4, Seena Dehkharghani5
1From the Diagnostic Imaging, Monash Medical Centre, Clayton, VIC, Australia (S.A.A.).
Abstract:
Background and Purpose- Accurate and rapid detection of anterior circulation large vessel occlusion (LVO) is of paramount importance in patients with acute stroke due to the potentially rapid infarction of at-risk tissue and the limited therapeutic window for endovascular clot retrieval. Hence, the optimal threshold of a new, fully automated software-based approach for LVO detection was determined, and its diagnostic performance evaluated in a large cohort study. Methods- For this retrospective study, data were pooled from: 2 stroke trials, DEFUSE 2 (n=62; 07/08-09/11) and DEFUSE 3 (n=213; 05/17-05/18); a cohort of endovascular clot retrieval candidates (n=82; August 2, 2014-August 30, 2015) and normals (n=111; June 6, 2017-January 28, 2019) from a single quaternary center; and code stroke patients (n=501; January 1, 2017-December 31, 2018) from a single regional hospital. All CTAs were assessed by the automated algorithm. Consensus reads by 2 neuroradiologists served as the reference standard. ROC analysis was used to assess diagnostic performance of the algorithm for detection of (1) anterior circulation LVOs involving the intracranial internal carotid artery or M1 segment middle cerebral artery (M1-MCA); (2) anterior circulation LVOs and proximal M2 segment MCA (M2-MCA) occlusions; and (3) individual segment occlusions. Results- CTAs from 926 patients (median age 70 years, interquartile range: 58-80; 422 females) were analyzed. Three hundred ninety-five patients had an anterior circulation LVO or M2-MCA occlusion (National Institutes of Health Stroke Scale 14 [median], interquartile range: 9-19). Sensitivity and specificity were 97% and 74%, respectively, for LVO detection, and 95% and 79%, respectively, when M2 occlusions were included. On analysis by occlusion site, sensitivities were 90% (M2-MCA), 97% (M1-MCA), and 97% (intracranial internal carotid artery) with corresponding area-under-the-ROC-curves of 0.874 (M2), 0.962 (M1), and 0.997 (intracranial internal carotid artery). Conclusions- Intracranial anterior circulation LVOs and proximal M2 occlusions can be rapidly and reliably detected by an automated detection tool, which may facilitate intra- and inter-instutional workflows and emergent imaging triage in the care of patients with stroke.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies VII: Vascular Imaging