Two-dimensional versus three-dimensional Frӓnkel Manoeuvre: a reproducibility study
Roberto Rongo1, Rosaria Bucci1, Raffaella Adaimo1
1School of Orthodontics, Department of Neurosciences, Reproductive Sciences and Oral Sciences, University of Naples 'Federico II', Naples, Italy.
European Journal of Orthodontics
|November 15, 2019
Summary
The Frӓnkel Manoeuvre (FM) is less reproducible using 3D scans compared to 2D pictures. This finding impacts diagnostic accuracy in orthodontic assessments of Class II malocclusion.
Area of Science:
- Orthodontics
- Dental Imaging
- Biomedical Engineering
Background:
- Skeletal Class II malocclusion is a common dental anomaly.
- The Frӓnkel Manoeuvre (FM) is a diagnostic tool used in orthodontics.
- Reproducibility of diagnostic methods is crucial for effective treatment planning.
Purpose of the Study:
- To evaluate the intra- and inter-observer reproducibility of the Frӓnkel Manoeuvre (FM) assessment.
- To compare the reproducibility of FM evaluation between 3D scans and 2D pictures.
- To determine the impact of imaging modality on the reliability of FM assessment.
Main Methods:
- 44 patients with skeletal Class II malocclusion were included.
- The Frӓnkel Manoeuvre (FM) was recorded using both 2D photography and 3D scanning.
- Six orthodontists and one gold standard evaluated the FM twice, with reproducibility assessed using Cohen's Kappa.
Main Results:
- Intra-observer agreement for FM assessment ranged from 0.36 to 1 on 2D pictures and 0.22 to 0.69 on 3D scans.
- Overall agreement was higher for 2D analysis (0.63) compared to 3D analysis (0.5).
- The reproducibility of the FM assessment was significantly lower when using 3D records.
Conclusions:
- The Frӓnkel Manoeuvre (FM) assessment demonstrates lower reproducibility with 3D scan data than with 2D photographic images.
- The choice of imaging modality influences the reliability of FM evaluation in orthodontic diagnosis.
- Further research may be needed to optimize 3D imaging techniques for orthodontic assessments.