Related Experiment Video
Updated: Jan 3, 2026

Low Molecular Weight Protein Enrichment on Mesoporous Silica Thin Films for Biomarker Discovery
Published on: April 17, 2012
Exploratory study on application of MALDI‑TOF‑MS to detect serum and urine peptides related to small cell lung
Panpan Lv1, Zeyuan Liu1, Bin Xu2
1Department of Pulmonary Oncology, The Fifth Medical Center of Chinese PLA General Hospital, Beijing 100071, P.R. China.
Abstract:
Matrix‑assisted laser desorption/ionization time‑of‑flight mass spectrometry (MALDI‑TOF‑MS) was employed to analyze differential serum and urine peptides in patients with small cell lung cancer (SCLC) and healthy individuals, and SCLC diagnostic classification models were constructed. Serum and urine samples from 72 patients with SCLC, age‑ and gender‑matched with 72 healthy individuals, were divided into training and testing sets in a 3:1 ratio. Serum and urine peptides were extracted using copper ion‑chelating nanomagnetic beads, and mass spectra were obtained using MALDI‑TOF‑MS. Peptide spectra for the training set were analyzed, and the classification model was constructed using ClinProTools (CPT). The testing set was used for blinded model validation. For training‑set sera, 122 differential peptide signal peaks with a mass of 0.8‑10 kDa were observed, and 19 peptides showed significantly different expression [P<0.0005; area under curve (AUC) ≥0.80]. CPT screened 5 peptide peaks (0.8114, 0.83425, 1.86655, 4.11133 and 5.81192 kDa) to construct the classification model. The testing set was used for the blinded validation, which had 95.0% sensitivity and 90.0% specificity. For the training‑set urine, 132 differential peptide signal peaks with m/z ratios of 0.8‑10 kDa were observed, and 8 peptides had significantly different expression (P<0.0005; AUC ≥0.80). Then, 5 peaks (1.0724, 2.37692, 2.7554, 4.75475 and 4.7949 kDa) were used for classification model construction. The testing set was used for 36 blinded validation, which had 85.0% sensitivity and 80.0% specificity. Among the differential peptides, 3 had the same significant peaks at 2.3764, 0.8778 and 0.8616 kDa, identified as fibrinogen α, glucose‑6‑phosphate isomerase and cyclin‑dependent kinase‑1, respectively. The present study highlighted the differences that exist in serum and urine peptides between patients with SCLC and healthy individuals. Serum and urine peptide diagnostic classification models could be constructed using MALDI‑TOF‑MS, and showed high sensitivity and specificity.
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
MALDI-TOF Mass Spectrometry

