Related Experiment Video
Updated: Jan 2, 2026

Strain Sensing Based on Multiscale Composite Materials Reinforced with Graphene Nanoplatelets
Published on: November 7, 2016
Sensing of Damage and Repair of Cement Mortar Using Electromechanical Impedance
Hussameldin Taha1, Richard J Ball1, Kevin Paine1
1BRE Centre for Innovative Construction Materials, Department of Architecture and Civil Engineering, University of Bath, Claverton Down BA2 7AY, UK.
Abstract:
Lead zirconium titanate (PZT) has recently emerged as a low-cost material for non-destructive monitoring for civil structures. Despite the numerous studies employing PZT transducers for structural health monitoring, no studies have assessed the effects of both damage and repair on the electromechanical impedance response in cementitious materials. To this end, this study was conducted to assess the effects of the damage and repair of mortar samples on the electromechanical response of a surface-mounted PZT transducer. When damage was introduced to the specimen in stages, the resonance frequencies of the admittance signature were shifted to lower frequencies as the damage increased, and an increase in the peak amplitude was detected, indicating an increase in the damping and a reduction in the material stiffness properties. Also, increasing the damage in the material has been shown to decrease the sensitivity of the PZT to further damage. During the repair process, a noticeable difference between the after-damage and the after-repair admittance signatures was noted. The root-mean-square deviation (RMSD) showed a decreasing trend during the repair process, when compared to the before repair RMSD response which indicated a partial recovery for the material properties by decreasing the damping property in the material.
More Related Videos
Related Concept Videos
Microcracking in Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Mortar Joint Deterioration in Masonry
The...
Soundness of Cement
Non-destructive Tests for Concrete Strength
Dynamic Modulus of Elasticity of Concrete