Related Experiment Video
Updated: Jan 2, 2026

Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Smart watch recording of ventricular tachycardia: Case study
Maxime Ringwald1, Alexandre Crich1, Nicolas Beysard1
1Emergency Department, Lausanne University Hospital, Lausanne, Switzerland.
Abstract:
Smartphones and connected devices allow patients to monitor their health in a variety of ways. We report the case of a patient presenting to the emergency department complaining of palpitations and syncope. Standard investigations were unremarkable. However, an electrocardiogram recorded through his Apple Watch® indicated ventricular tachycardia. This case highlights the importance of proactively requesting such information from patients, though normal recordings may not preclude cardiac arrhythmia. Controlled clinical studies are needed to validate such practices.