Related Experiment Video
Updated: Jun 30, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
A rapid method for on-line solid-phase extraction and determination of dioscin in human plasma using a homemade
Shan Peng1,2, Ligai Bai3,4, Xiaoqian Shi1
1College of Pharmaceutical Sciences, Hebei University, No. 180 Wusi East Road, Baoding, 071002, Hebei, China.
Abstract:
A phenyl-based polymer monolithic column was prepared via free radical polymerization in a stainless steel column with the size of 4.6 mm i.d. × 50 mm, using ethylene glycol phenyl ether acrylate as the monomer. The resulting monolithic column shows high porosity of 73.42% and relative uniform pore structure, as characterized by mercury porosimetry and scanning electron microscopy, respectively. The optimized polymer monolith column was used for on-line solid-phase extraction prior to the reversed phase mode HPLC-UV analysis for the determination of dioscin in human plasma, using a COSMOSIL C18 column (4.6 mm × 150 mm, 4.5 μm). Water was used to wash non-retained components from the SPE sorbent, and methanol water (80:20, V/V) was used as the mobile phase for isocratic elution of dioscin. The maximum adsorbed quantity of dioscin to the SPE column is 6.79 mg/g, which is high enough for the quantitative analysis of dioscin in plasma, due to the low content of dioscin in plasma. The method was validated by assessing the linearity, lower limit of quantification, intra- and inter-day precision, accuracy, and repeatability. The developed method was applied for the analysis of dioscin in plasma from a volunteer who had orally administered an aqueous extract of dioscorea nipponica rhizome, showing the method capable of detecting dioscin in the plasma. These results show that the developed method is a rapid method for on-line solid-phase extraction and determination of dioscin from plasma, exhibiting good selectivity with hydrogen bond interaction and hydrophobic interaction, good clean-up ability, cost-saving, and time-saving. Graphical abstract.
More Related Videos
10:09A Straightforward Method for Glucosinolate Extraction and Analysis with High-pressure Liquid Chromatography HPLC
Published on: March 15, 2017
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Supercritical Fluid Chromatography