Aim:
The aim of the study was to evaluate and compare the vertical marginal discrepancy of computer-aided design (CAD)/computer-aided manufacturing (CAM) and pressable lithium disilicate onlays.
Materials And Methods:
A maxillary first premolar typodont tooth was prepared to receive lithium disilicate onlay. Mesio-occluso-distal cavity was prepared with palatal cusp reduction and collar preparation. In the proximal box, gingival seat was placed 1 mm coronal to the cementoenamel junction and mesiodistal width of the seat was kept to 1 mm. Thirty stone models were prepared from thirty rubber base impressions and divided into two groups, based on the technique of fabrication of onlays: (1) Group CL (CAD/CAM lithium disilicate) and (2) Group PL (Pressable lithium disilicate). Fifteen onlays per each group were fabricated by following the manufacturer instructions. Marginal fit of all the samples were analyzed by using stereomicroscope with Image Analysis software. Statistical analysis was done by t-test.
Results:
Statistical significant difference was found between both the groups. The lowest marginal discrepancy (41.46 μm) was measured for Group CL (CAD/CAM lithium disilicate) specimens, and the highest (55.95 μm) discrepancy was observed on the Group PL (Pressable lithium disilicate) specimens.
Conclusion: