Validation of wearable activity monitors for real-time cadence
Ho Han1, Heontae Kim2, Wei Sun1
1Health Education & Promotion Program, School of Community Health Sciences, Counseling and Counseling Psychology, Oklahoma State University, Stillwater, OK, USA.
Abstract:
The purpose of this study is to establish evidence of validity for wearable activity monitors providing real-time cadence against a criterion measure. Thirty-six healthy adults, aged 18-65 years, participated in the study. Four activity monitors including 2 watch-based monitors and 2 cadence sensors attaching to shoelaces were tested. Each participant completed the study protocol consisting of 2 distinct components: (1) treadmill protocol and (2) overground protocol. Lin's concordance correlation and mean absolute percentage error (MAPE) were calculated for the comparisons between the criterion and measures of the monitors. Bland-Altman analysis was performed to determine the mean bias and 95% limits of agreement. All activity monitors showed high correlations with the criterion measures (p < .01). Lower correlations were observed at slow walking speeds in the watch-based monitors. In contrast, consistent and strong correlations were found with both cadence sensors regardless of walking speeds (p < .01). Similar patterns were observed in the MAPE scores. Greater than 90% of the participants were able to maintain prescribed walking intensity using real-time cadence. The results suggest that the wearable activity monitors are an acceptable measure of real-time cadence and provide the potential to improve intensity-based prescription of physical activity using the monitors.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Holter Monitor: 24-Hour Monitoring
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...