Related Experiment Video
Updated: Dec 31, 2025

A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
Stress-Swelling Finite Element Modeling of Cervical Response With Homeostatic Collagen Fiber Distributions
Kun Gou1, Heiko Topol2, Hasan Demirkoparan2
1Department of Science and Mathematics, Texas A&M University-San Antonio, San Antonio, TX 78224.
During pregnancy, the cervix experiences significant mechanical property change due to tissue swelling, and to ongoing changes in the collagen content. In this paper, we model how these two effects contribute to cervical deformation as the pressure load on top of the cervix increases. The cervix and its surrounding supporting ligaments are taken into consideration in the resulting mechanical analysis. The cervix itself is treated as a multilayered tube-like structure, with layer-specific collagen orientation. The cervical tissue in each layer is treated in terms of a collagen constituent that remodels with time within a ground substance matrix that experiences swelling. The load and swelling are taken to change sufficiently slowly so that the collagen properties at any instant can be regarded as being in a state of homeostasis. Among other things, the simulations show how the luminal cross-sectional area varies along its length as a function of pressure and swelling. In general, an increase in pressure causes an overall shortening of the lumen while an increase in swelling has the opposite effect.
During pregnancy, the cervix experiences significant mechanical property change due to tissue swelling, and to ongoing changes in the collagen content. In this paper, we model how these two effects contribute to cervical deformation as the pressure load on top of the cervix increases. The cervix and its surrounding supporting ligaments are taken into consideration in the resulting mechanical analysis. The cervix itself is treated as a multilayered tube-like structure, with layer-specific collagen orientation. The cervical tissue in each layer is treated in terms of a collagen constituent that remodels with time within a ground substance matrix that experiences swelling. The load and swelling are taken to change sufficiently slowly so that the collagen properties at any instant can be regarded as being in a state of homeostasis. Among other things, the simulations show how the luminal cross-sectional area varies along its length as a function of pressure and swelling. In general, an increase in pressure causes an overall shortening of the lumen while an increase in swelling has the opposite effect.
Related Concept Videos
Members Made of Elastoplastic Material
As the bending moment...
Temperature Dependent Deformation
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Residual Stresses in Bending
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....

